User`s manual

Mediant 1000
H.323 User's Manual 44 Document #: LTRT-83401
¾ To clean / replace the air filter, take these 7 steps:
1. Release the two screws on the top right-hand corner and the bottom right-hand corner
of the front panel of the fan tray unit.
2. Pull the fan tray unit outward. Figure 3-9 below shows the fan tray unit slightly
extracted.
Figure 3-9: Slightly Extracted Fan Tray Unit
3. With your fingertips, grasp the steel frame of the air filter and separate it from the fan
tray unit; you should be able to remove it relatively easily. Figure 3-10 below shows
the air filter extracted from the fan tray unit.
Figure 3-10: Fan Tray with Filter Extracted
4. Take one of the following steps:
If you are cleaning the filter, use a vacuum cleaner (set to light suction) to remove
dust particles from the filter.
Alternatively, if you are replacing the filter, discard the old air filter and replace it
with an air filter purchased from AudioCodes.