User`s manual

H.323 User's Manual 5. Web Management
Version 5.0 59 December 2006
Submenu bar: appears on the top of screens and contains submenu options.
Main action frame: the main area of the screen in which information is viewed and
configured.
Home icon: when clicked it opens the Home page screen (refer to Section 5.10 on
page 197).
Corporate logo: AudioCodes’ corporate logo. For information on how to remove this
logo Section 11.5 on page 303.
Search engine: for searching ini file parameters configurable by using the Embedded
Web Server (refer to Section 5.4.4 on page 60).
Control Protocol: the Mediant 1000 control protocol.
5.4.1 Main Menu Bar
The main menu bar of the Web Interface is divided into the following menus:
Quick Setup: Use this menu to configure the gateway’s basic settings; for the full list
of configurable parameters go directly to ‘Protocol Management’ and ‘Advanced
Configuration’ menus. An example of the Quick Setup configuration is described in
Section 4.2.3 on page 49.
Protocol Management: Use this menu to configure the gateway’s control protocol
parameters and tables (refer to Section 5.4.4 on page 60).
Advanced Configuration: Use this menu to set the gateway’s advanced
configuration parameters (for advanced users only) (refer to Section 5.6 on page 129).
Status & Diagnostics: Use this menu to view Syslog messages, hardware / software
product information, and to assess the gateway’s statistics and IP connectivity
information (refer to Section 5.7 on page 177).
Software Update: Use this menu when you want to load new software or
configuration files onto the gateway (refer to Section 5.8 on page 184).
Maintenance: Use this menu to remotely lock/unlock the device (refer to Section 5.9.1
on page 192), save configuration changes to the non-volatile flash memory (refer to
Section 5.9.2 on page 193), and reset the gateway (refer to Section 5.9.3 on page
195).
When positioning your curser over a parameter name (or a table) for more than 1 second,
a short description of this parameter is displayed. Note that parameters preceded by an
exclamation mark (!) are not changeable on-the-fly and require that the device be reset.
5.4.2 Saving Changes
To save changes to the volatile memory (RAM) click the Submit button (changes to
parameters with on-the-fly capabilities are immediately available, other parameter are
updated only after a gateway reset). Parameters that are only saved to the volatile memory
revert to their previous settings after hardware reset. When performing a software reset
(i.e., via Web or SNMP) you can choose to save the changes to the non-volatile memory.
To save changes so they are available after a power fail, you must save the changes to the
non-volatile memory (flash).
To save the changes to flash, refer to Section 5.9.2 on page 193.
5.4.3 Entering Phone Numbers in Various Tables
Phone numbers entered into various tables on the gateway, such as the Tel to IP routing
table, must be entered without any formatting characters. For example, if you wish to enter
the phone number 555-1212, it must be entered as 5551212 without the hyphen (-). If the
hyphen is entered, the entry does not work. The hyphen character is used in number entry
only, as part of a range definition. For example, the entry [20-29] means ‘all numbers in the
range 20 to 29’.