Table 5-8: Supplementary Services Parameters (continues on pages 86 to 88)
Parameter Description
Number of Call Waiting
Indications
[NumberOfWaitingIndicati
ons]
Number of waiting indications that are played to the receiving side of the call (FXS
only) for Call Waiting.
The default value is 2.
Time Between Call Waiting
Indications
[TimeBetweenWaitingIndi
cations]
Difference (in seconds) between call waiting indications (FXS only) for Call
Waiting.
The default value is 10 seconds.
Time Before Waiting
Indication
[TimeBeforeWaitingIndica
tion]
Defines the interval (in seconds) before a call waiting indication is played to the
port that is currently in a call (FXS only).
The valid range is 0 to 100. The default time is 0 seconds.
Waiting Beep Duration
[WaitingBeepDuration]
Duration (in msec) of waiting indications that are played to the receiving side of the
call (FXS only) for Call Waiting.
The default value is 300.
Enable Caller ID
[EnableCallerID]
Disable [0] = Disable the Caller ID service (default).
Enable [1] = Enable the Caller ID service.
If the Caller ID service is enabled, then for FXS modules, calling number and
Display text are sent to gateway port.
For FXO modules, the Caller ID signal is detected and is sent to IP in H.323 Setup
message (as Calling number and ‘Display’ text).
For information on the Caller ID table, refer to Section
5.5.7.3 on page 116.
To disable/enable caller ID generation per port, refer to Section 5.5.7.5 on page
118.
Caller ID Type
[CallerIDType]
Defines one of the following standards for detection (FXO) and generation (FXS)
of Caller ID and detection (FXO) of MWI (when specified) signals.
Bellcore [0] (Caller ID and MWI) (default).
ETSI [1] (Caller ID and MWI)
NTT [2]
Backward Compatible [3]
British [4]
DTMF ETSI [16]
Denmark [17] (Caller ID and MWI)
India [18]
Brazil [19]
Note 1: The Caller ID signals are generated/detected between the first and the
second rings.
Note 2: To select the Bellcore Caller ID sub standard, use the parameter
‘BellcoreCallerIDTypeOneSubStandard’. To select the ETSI Caller ID sub
standard, use the parameter ‘ETSICallerIDTypeOneSubStandard’.
Note 3: To select the Bellcore MWI sub standard, use the parameter
‘BellcoreVMWITypeOneStandard’. To select the ETSI MWI sub standard, use the
parameter ‘ETSIVMWITypeOneStandard’.
Message Waiting Indication (MWI) Parameters
Enable MWI
[EnableMWI]
Disable [0] = Disabled (default).
Enable [1] = H.450.7 MWI service is enabled.
This parameter is applicable only to FXS modules.
Note: The Mediant 1000 only supports reception of MWI.
MWI Analog Lamp
[MWIAnalogLamp]
Disable [0] = Disable (default).
Enable [1] = Enable visual Message Waiting Indication, supplies line voltage of
approximately 100 VDC to activate the glow lamp (on a phone that is equipped
with an MWI lamp).
This parameter is applicable only to FXS modules.