Specifications

14.0 Upgrading Firmware
What to do if flash upgrade fails or is interrupted:
1) Download latest copy of Flash123 from www.auroramultimedia.com under the TVP-1000 product
section.
2) Download the latest version of firmware.
3) Install Flash123 on a Windows 2000 or better machine.
4) With the Plasma off connect the 6 pin Mini Din to 9 pin RS232 cable between the Control port of
the TVP-1000 and the Com port of the PC. Do not try to upgrade firmware going through the
Plasma RS-232. If you do not have a cable the help menu of Flash123 has the pin out.
5) Next, turn the power on to the Plasma and launch the Flash123 program.
6) Select the Com port, then the file, then click on start. The firmware should start uploading. This
process could take a few minutes. Do not turn off the power to the Plasma or unplug the RS-232
cable when uploading firmware.
Well everyone needs a backup plan just in case.
If a flash upload is interrupted, Flash123 will not work unless
Hardware Boot is checked under the options selection.
By selecting this, you are telling the Flash123 program
it is still in firmware upgrade mode. Once checked cycle
the power to the plasma using the remote then click
on start again.
If this still does not work please call Aurora Multimedia technical support for assistance.