User manual

User Manual Page 20 of 74
(PVI-6000-OUTD-UK-W Rev.1.0)
3.4 Wall mounting
AURORA should be mounted in a vertical position as shown in Fig.6.
The package includes a hardware kit with three 6.3x70 steel screws and 3 SX10 wall
anchors for installation of a metal bracket to a masonry wall. Screws and wall anchors
can be installed using 3 of the 5 holes available on the bracket (reference part C in the
pictures below).
WARNING: Bracket shall be mounted vertically on wall: spring side shall
face up, while side with M6 PEM shall face down.
Since the wall can be made from different construction materials, it is the installer's
responsibility to provide suitable mounting hardware. We recommend using stainless
steel screws.
For concrete wall mounting the hole should be min. 8 mm in diameter and min. 70 mm
deep.
Hang AURORA on the spring at the bracket top, by means of the metal mount
fastened to the upper part at inverter back. The central part of this plate features a seat
for fastening the spring (see Part A in Fig. 6).
Once inverter top end is secured in place, you need to secure its bottom end.
From inverter front, use an M6x10 screw and washer to secure the unit to the bracket
PEM, starting with the center slot of the lower plate (Part B in Fig. 6).
FRONT BACK
Part.A
Part.B