Fig.6 -. AURORA wall mounting
NOTE: Ensure that the AURORA inverter is not exposed to direct sun
radiation or other external heat sources, including the units installed
underneath it (see Fig. 7). If several inverters are stacked up, the heat
generated by the inverters placed at the bottom of the stack could cause
ambient temperature to rise and affect the operation of the inverters in the
upper rows. Temperatures exceeding 40°C could result in the derating of the
output power of the units placed in the upper rows.
A combination of high output power and high ambient temperature will result
in a significant power derating and a lower energy production. For proper
cooling, make sure to install AURORA to allow unobstructed air flow (for
instance, the front panel should never face a solid surface).