User manual

User Manual Page 56 of 74
(PVI-6000-OUTD-UK-W Rev.1.0)
Fig. 22 - Alarm contacts terminal block
This function can activate two alarm modes. Press ENTER to open the relevant
submenu:
An arrow on the left side of the display highlights your current selection. When an
item is selected, press ENTER to confirm activation of chosen mode.
PRODUCTION: Relay is only activated when the inverter is connected to the grid
(contact closing across terminals “N.O.” and “C”)
FAULT: triggers relay activation (contact closing across terminals “N.O.” and “C”),
only when an error signal occurs, i.e. when grid is disconnected, excluding Input
Undervoltage.
5.5.6.11 Remote control
This function is used to disable the inverter’s manual shutdown. Operation is as
follows:
- set to ENABLE to activate manual ON/OFF function
- set to DISABLE to disable manual ON/OFF function, so that the inverter will be
automatically controlled only by the input voltage.
Production
Fault
Remote ON/OFF
Disable
Remote ON/OFF
Enable