User manual

User Manual Page 70 of 74
(PVI-6000-OUTD-UK-W Rev.1.0)
8.2 Output Value
Description
Value
PVI – 6000 – OUTD – UK -W
Nominal output power 6,000 W
Grid voltage, maximum range 180 to 264 Vac
Grid voltage, nominal 230 Vac
Grid voltage, operating range
82% to 115% of nominal voltage
(188.6 to 264Vac for V=230Vac)
Grid frequency, maximum range 47 to 63 Hz
Grid frequency, nominal 50 Hz
Grid frequency, operating range 49.72 to 50.28 Hz
Nominal output current 26 Arms
Max. output current 30 Arms
Output over current protection 40 Arms
8.3 Grid protection characteristics
Anti islanding protection Complies with G83/1 standard.