dedicated KVM switch and rackmount screen technology User Manual 19” LCD RP-919QD 9U Quad Display Options : - DC power 751 Designed and manufactured by Austin Hughes UM-CV-751-RP-919QD-Q215V1 www.austin-hughes.
Legal Information First English printing, October 2002 Information in this document has been carefully checked for accuracy; however, no guarantee is given to the correctness of the contents. The information in this document is subject to change without notice. We are not liable for any injury or loss that results from the use of this equipment. Safety Instructions Please read all of these instructions carefully before you use the device. Save this manual for future reference.
Contents < Part. 1 > RP-W919QD 1.1 1.2 1.3 Package Content Structure Diagram & Dimension Installation P.1 P.1 - 2 P.3 < Part. 2 > Specifications / OSD 2.1 2.2 Product Specifications On-screen Display Operation ( OSD ) P.4 - 5 P.6 < Part. 3 > Options 3.1 DC Power : 12V / 24V / 48V / 110 ~ 125V P.7 < Part. 4 > Quad Display Connection & Operation 4.1 4.2 4.3 4.4 4.5 4.6 4.
< Part 1 > < 1.1 > Package Content RP-919QD unit X 1 - 6ft VGA cable X 1 - Power adapter X 1 - Power cord X 1 < 1.2 > Structure Diagram Front view 1 2 Power adapter 3 Rear view 4 1 LCD panel 2 LCD OSD membrane 3 Quad display control membrane 4 Power adapter basket Power cord Option : DC power UM-CV-751-RP-919QD-Q215V1 P.1 www.austin-hughes.
< 1.2 > Dimension RP-919QD Front View Side View UNIT : mm 1mm = 0.03937 inch Bottom View Model Product Dimension (W x D x H) Packing Dimension (W x D x H) Net Weight Gross Weight RP-919QD 480 x 68.5 x 399 mm 18.9 x 2.7 x 15.7 inch 583 x 124 x 529 mm 23 x 4.9 x 20.8 inch 9.5 kg 20.9 lbs 12.5 kg 27.5 lbs UM-CV-751-RP-919QD-Q215V1 P.2 www.austin-hughes.
< 1.3 > Installation Step ■ ■ 1 Mount the display panel with M6 screw set. M6 screw x 8 pcs required ( Left & right side ). M6 screw sets are not provided. D LC nu Me < < < ad Qu D OS > ol ntr y Co pla Dis SEQ VCR p Setu Step ■ D LC ol ntr y Co pla Dis Fix the LCD into the rack. nu Me > < < < ad Qu D OS 2 SEQ VCR p Setu UM-CV-751-RP-919QD-Q215V1 P.3 www.austin-hughes.
< Part 2 > < 2.1 > Product Specifications LCD Panel RP-919QD Manufacturer Panel Size ( diagonal ) 19-inch TFT color LCD Display pixel ( dots x lines ) 1280 x 1024 Brightness ( typ. ) 250 Contrast Ratio ( typ. ) 1000:1 Color 16.7 M Viewing Angle ( L/R/U/D ) 85/85/80/80 Response Time ( ms ) 5 Dot pitch ( mm ) 0.294 Display Area ( mm ) 376.32H x 301.
Physical Specification Product ( W x D x H ) 480 x 68.5 x 399 mm 18.9 x 2.7 x 15.7 inch Packing ( W x D x H ) 583 x 124 x 529 mm 23 x 4.9 x 20.8 inch Applicable Format Net Weight 9.5 kgs / 20.9 lbs Gross Weight 12.5 kgs / 27.
RP-919QD < 2.
< Part 3 > < 3.1 > Options : DC Power Model 12V 24V 48V 110 ~ 125V Input voltage: 12-Volt 24-Volt 48-Volt 110-Volt Input range: 9 ~ 18V 18 ~ 36V 36 ~ 75V 66 ~ 160V - No load 50 mA 50 mA 50 mA 40 mA - Full load 4950 mA 2450 mA 1220 mA 993 mA Output voltage: 12-Volt 12-Volt 12-Volt 12-Volt Output current: 4.16A 4.16A 4.16A 8.4A Efficiency 84% 85% 85% 92% Input rating Input current Output rating UM-CV-751-RP-919QD-Q215V1 P.7 www.austin-hughes.
< Part 4 > < 4.1 > QD Connection RP-919QD 1. VCR in : This BNC connector is connected to video output from VCR/DVR. A pre-recorded quad screen signal from a tape can be played back through a VCR/DVR and displayed on the video output channels. Push the VCR button (#2) to switch the device to VCR Playback mode. 2. VCR out : This BNC connector is to be connected to the Video in from your VCR/DVR. It will only provide a quad screen video to ensure an un-interrupted video recording for all four cameras.
< 4.2 > QD ALARM Connection & Operation 1. ALARM I/O : This female type 9 pin D-sub connector is used for alarm sensor input and alarm output control connections. It provides Normal Open and Normal Close contacts for alarm out control.
RP-919QD < 4.2 > QD ALARM Connection & Operation 3 Sensor Activated Alarm The unit is equipped with 4 alarm sensor inputs. If any alarm is activated: ■ ■ ■ the built-in buzzer and the alarm output control relay contact will be activated. the quad will switch the corresponding channel indicator LED to blinking mode.
< 4.3 > QD Remote Control Connection & Operation Rear Panel IN hi-z 1 2 3 4 RS-232 OUT dc 12V, 1amp ALARM I/O monitor vcr 75 RS-232 Cable Wire Computer UM-CV-751-RP-919QD-Q215V1 P.11 Remote Keypad www.austin-hughes.
RP-919QD < 4.3 > QD Remote Control Connection & Operation The device can be controlled via the male type 9 pin D-sub/RS-232 connector to a computer using ASCII code. 1.
< 4.3 > QD Remote Control Connection & Operation *1. In order to control the device to operate in Zoom mode, the computer has to first send command code ” to switch the signal source from camera to VCR/DVR, at this time the device will automatically zoom channel 1 video from VCR/DVR to full screen. User can then input a corresponding channel code to zoom any other specific channel.
RP-919QD < 4.3 > QD Remote Control Connection & Operation 2.3 The configuration of the status code for both normal and alarm operations: There are total 2 bytes of the status codes. Byte one, the first 8 bits, shows the current status of the operation modes that the unit is in. Byte two, the second 8 bits, shows the current status of the alarm operations of the unit.
< 4.3 > QD Remote Control Connection & Operation BYTE 2: Status code for alarm operations: The first 4 bits show the sensor activated alarm status of each channel; next 4 bits show the video loss alarm status of each channel. The digit “1” means alarm event is detected, and “0” means no alarm event is detected.
< 4.4 > QD OSD Operation RP-919QD 3 1 Quad Display Control SEQ VCR < 2 4 < < Setup > 5 1 Lock: Security locks out button. Push this button for 2 seconds to enable control panel lock out function. Push this button again for 2 seconds to disable the function. 2 VCR: Push this button to enter into VCR Playback/Zoom operation. In this mode, the output video is displaying the video signal from VCR.
< 4.5 > QD On-screen Menu Right after the unit is turned on, The monitor will display the last setting on the Setup Menu. 1. Page 1 of the Setup Menu - Display Setting Push Setup buttons (#1, #2) simultaneously to display the Setup Menu on the screen. There are total two pages in the Setup Menu. Page 1 is used to program TIME, DATE, and camera TITLE. Page 2 is used to program Alarm Operations. Under this mode, channel selection buttons (#5) on the front panel are used for cursor control and text selection.
RP-919QD < 4.5 > QD On-screen Menu 2 Page 2 of the setup menu- Alarm Setting Push Setup buttons (#1, #2) simultaneously and push (#1) button again to display page 2 of the setup menu on the screen. This Alarm Setting menu is used to set the desired alarm configuration like sensor type, sensor sensitivity, alarm hold duration, and buzzer. ALARM SETTING CH SENSOR TYPE 1 OPEN NO 2 OPEN NO 3 OPEN NO 4 OPEN NO SENSITIVITY: DURATION: BUZZER: V-LOSS ALARM: V-LOSS RELAY: STATUS ON ON ON ON 0.
< 4.5 > QD On-screen Menu 4: The setup menu can be reset to factory setting by pushing the Setup buttons (#1, #2) and power on the quad simultaneously.
RP-919QD < 4.6 > QD VCR Operation Zoom on VCR playback operation: Push VCR button (#2) to ON will switch the device to VCR playback mode. Under this mode, if the device is on quad display mode, a pr-recorded quad display video in the tape will be shown on the screen. If the device is in Full screen display mode, push any channel select buttons (#5) will select and expand the corresponding quadrants of the prerecorded video to full screen display. < 4.
The company reserves the right to modify product specifications without prior notice and assumes no responsibility for any error which may appear in this publication. All brand names, logo and registered trademarks are properties of their respective owners. Copyright 2015 Austin Hughes Electronics Ltd. All rights reserved. UM-CV-751-RP-919QD-Q215V1 www.austin-hughes.