Installation guide

CT-3400 TW Installation Guide P.17
Smart Secure Lock
If the vehicle is initially locked, at remote START the Module will send an UNLOCK/Disarm pulse before
start-up,
LOCK/Arm again when the engine is running, and LOCK/Arm once again 4 sec. after it shuts
shut down the engine.
If the vehicle is initially unlocked, upon remote start the module will start the engine and arm the
starter kill, but the doors will not be locked or unlocked at any moment of the sequence.
Priority Door Access
(Both AUX 1 and AUX 2 can be programmed for Priority Door Access.) This great feature allows
the user to
UNLOCK solely the driver’s door with a single press of the UNLOCK button on the
transmitter, and to
UNLOCK the other doors, if desired, by pressing the UNLOCK button for a second
time.
The output will provide a 1-sec negative output when the
UNLOCK button is pressed a second time
on the transmitter. This can be used not only as priority door access, but also as trunk release.
The AUX 2 Timed Output
This 500 mA negative AUX 2 output can be used for many different applications. It can be
programmed for priority door access if
AUX 1 is programmed for horn confirmation.
To activate the
AUX 2 output, press F and then LOCK button.
The AUX 3 / Trunk or Sunroof Output
This 500 mA negative AUX 3 output can be used for many different applications. The output can be
programmed to give a 1-sec. pulse when the
TRUNK button is pressed (if the ignition is OFF or when
Ignition is
ON after a remote start) or to give a continuous output as long as the TRUNK button is held
down (for sunroof or window control).
Note
In Trunk mode, the output will operate only if the Ignition is OFF or if the
engine is running under the control of the module.
If AUX 3 is programmed for a 1-second TRUNK signal, you will need to hold the
TRUNK button down for 3 seconds in order to activate the trunk.
Trunk 2 Output with Disarm / Rearm Pulse
When the Trunk 2 Option is selected (Mode 3, Function 4, Option 3), a Disarm pulse will be sent
before the trunk is popped. An arm pulse will be sent 4 seconds later. This option is overridden when
the Zone 3 Bypass is used as a trunk pin (Mode 3, Function 5, Option 1).
Programmable External Trigger
The External Trigger wire can be connected to a trunk pin-switch generating a negative signal when
the trunk is open.
Smart Ignition Locks
This feature can be enabled by connecting the external trigger (the 9
th
pin of the 12-pin harness) input
to a negative door sense wire when the door is open (usually the Dome Light) and by programming
the external trigger input accordingly (Option 4).
When the ignition-controlled door locks are active and the engine is running, whenever the brake
pedal is pressed while a door has been opened and closed again since the last
LOCK pulse was sent,
the system will relock all doors at once.