Use and Care Manual

www.factorybuysdirect.com
3160946-01A
SAFETY
FBDTP15 FBDTP30
Rating 10,000 - 15,000 Btu/hr
(3.0 - 4.4 kW)
10,000 - 30,000 Btu/hr
(3.0 - 8.8 kW)
Type of Gas Propane/LP Only
Ignition Match Light
Gas Supply Pressure
to regulator
Max - Tank Pressure
Min - 20 psi (1.37 bar)
Manifold Pressure 9 - 17 psi (0.62 bar - 1.17 bar)
Minimum Ambient Temperature Rating 0° F (-17.8° C)
Fuel Consumption per 20 lb. Cylinder 36 Hours 18 Hours
Refer to the specification section of
the heaters manual, heater data plate,
or contact ProCom Heating, Inc. to
determine combustionair ventilation
requirements of the heater.
• Lackofproperventilationairwilllead
toimpropercombustion.
• Impropercombustioncanleadtocar-
bonmonoxide poisoningleading to
serious injury or death. Symptom of
carbonmonoxidepoisoningcaninclude
headachesdizziness anddifculty in
breathing.
1. Keep children and animals away from
heater.
2. Never operate heater while sleeping or
unattended.
3. Check the heater thoroughly for damage.
Do not operate a damaged heater.
4. Do not modify the heater or operate a
heater which has been modied from its
original condition.
5. Use only propane/LP gas.
6. Use only vapor withdrawal propane/LP
supply. If there is any question about
vapor withdrawal, ask your propane/LP
dealer.
7. For indoor use only. Adequate ventilation
must be provided. Provide minimum open-
ings of 1 sq ft (0.093 m²) near the oor and
1 sq ft. (0.093 m²) near the ceiling. Do not
use inside house, camper, tent, vehicle, or
any type of unvented or enclosed area.
WARNING: This product
contains and/or generates
chemicals known to the State
of California to cause cancer or
birthdefects,orotherreproduc-
tiveharm.
WARNING: Not for home or
recreationalvehicleuse.
The heater is designed and approved for use
as a construction heater in accordance with
Standard ANSI Z83.7 • CSA 2.14. Check with
your local re safety authority if you have
questions about applications.
Other standards govern the use of fuel gases
and heat producing products in specic ap-
plications. Your local authority can advise you
about these.
The intended use of this heater is the tempo-
rary heating of buildings or structures under
construction, alteration or repair.
ASPHYXIATION HAZARD
Do not use this heater for heating human
livingquarters.
• Donotuseinunventilatedareas.
• Theowofcombustionandventilation
airmustnotbeobstructed.
• Properventilationairmustbeprovided
tosupportthecombustionairrequire-
mentsoftheheaterbeingused.
SPECIFICATIONS