Use and Care Manual
www.factorybuysdirect.com
3160946-01A
SAFETY
FBDTP15 FBDTP30
Rating 10,000 - 15,000 Btu/hr
(3.0 - 4.4 kW)
10,000 - 30,000 Btu/hr
(3.0 - 8.8 kW)
Type of Gas Propane/LP Only
Ignition Match Light
Gas Supply Pressure
to regulator
Max - Tank Pressure
Min - 20 psi (1.37 bar)
Manifold Pressure 9 - 17 psi (0.62 bar - 1.17 bar)
Minimum Ambient Temperature Rating 0° F (-17.8° C)
Fuel Consumption per 20 lb. Cylinder 36 Hours 18 Hours
• Refer to the specification section of
the heater’s manual, heater data plate,
or contact ProCom Heating, Inc. to
determine combustionair ventilation
requirements of the heater.
• Lackofproperventilationairwilllead
toimpropercombustion.
• Impropercombustioncanleadtocar-
bonmonoxide poisoningleading to
serious injury or death. Symptom of
carbonmonoxidepoisoningcaninclude
headachesdizziness anddifculty in
breathing.
1. Keep children and animals away from
heater.
2. Never operate heater while sleeping or
unattended.
3. Check the heater thoroughly for damage.
Do not operate a damaged heater.
4. Do not modify the heater or operate a
heater which has been modied from its
original condition.
5. Use only propane/LP gas.
6. Use only vapor withdrawal propane/LP
supply. If there is any question about
vapor withdrawal, ask your propane/LP
dealer.
7. For indoor use only. Adequate ventilation
must be provided. Provide minimum open-
ings of 1 sq ft (0.093 m²) near the oor and
1 sq ft. (0.093 m²) near the ceiling. Do not
use inside house, camper, tent, vehicle, or
any type of unvented or enclosed area.
WARNING: This product
contains and/or generates
chemicals known to the State
of California to cause cancer or
birthdefects,orotherreproduc-
tiveharm.
WARNING: Not for home or
recreationalvehicleuse.
The heater is designed and approved for use
as a construction heater in accordance with
Standard ANSI Z83.7 • CSA 2.14. Check with
your local re safety authority if you have
questions about applications.
Other standards govern the use of fuel gases
and heat producing products in specic ap-
plications. Your local authority can advise you
about these.
The intended use of this heater is the tempo-
rary heating of buildings or structures under
construction, alteration or repair.
ASPHYXIATION HAZARD
• Do not use this heater for heating human
livingquarters.
• Donotuseinunventilatedareas.
• Theowofcombustionandventilation
airmustnotbeobstructed.
• Properventilationairmustbeprovided
tosupportthecombustionairrequire-
mentsoftheheaterbeingused.
SPECIFICATIONS