8. Do not use heater in basement or below
ground level.
9.
Before connecting heater to the propane/LP
tank, make sure the heater regulator knob
is in the OFF position. Always connect and
light heater in areas free of open ames.
10. Mount the propane/LP cylinders vertically
(shutoff valve up). Secure them from fall-
ing or being knocked over and protect
them from damage.
11. IMPORTANT: Use only hose and regulator
assembly provided with the dual burner
tank top heater. Inspect hose assembly
before each use. If there is excessive
abrasion or wear, or hose is cut, replace
with hose assembly listed on parts list
before using heater. Hose and regulator
must be protected from damage.
12. The heater burner must be at least 2 ft.
(0.61 m) above the oor. Always attach
to propane/LP tank in an upright position.
Never operate a heater on its side or at-
tach to propane/LP tank in a horizontal
position. This could lead to dangerous
are-ups or re. Do not direct heat toward
propane/LP cylinders within 20 ft (6 m).
13. Maintain minimum clearance from nor-
mal combustible materials (like paper)
as follows:
Sides and Top 3 ft. (0.91 m)
Front 6 ft. (1.8 m)
Floor to Bottom of Burner 2 ft. (0.6 m)
Locate 10 ft. (3 m) from canvas or plastic
tarpaulins or similar coverings and secure
them to prevent apping or movement due
to wind action.
SAFETY
14. The appliance area be kept clear and free
from combustible materials, gasoline and
other ammable vapors and liquids.
15. If at any time gas odor is detected, IM-
MEDIATELY DISCONTINUE operation
until the source of gas has been located
and corrected.
16. Install the heater such that it is not directly
exposed to water spray, rain, dripping
water and/or wind.
17. Position heater properly before use. Oper-
ate only on a stable, level surface.
18. Due to the high surface and exhaust
temperatures, adults and children must
observe clearances to avoid burns or
clothing ignition.
19. Do not move, handle or service while hot
or burning. Do not attach or remove a hot
or operating heater from the propane/LP
tank.
20. Before each use, check heater for leaks.
Never use an open ame to check for
leaks. Apply a mixture of liquid soap and
water to all joints. Bubbles forming show
a leak. Correct all leaks.
21. Keep all connections and ttings clean.
Make sure propane/LP tank valve is clean.
Check "O" ring on heater inlet fuel valve
connector for damage before each use.
Replace if worn or damaged.
22. Use only in accordance with local codes
or, in the absence of local codes, with the
Standard for the Storage and Handling of
Liqueed Petroleum Gases ANSI/NFPA
58 and CSA B149.1, Natural Gas and
Propane Installation Code.