Product specifications

Replacing System Drives in the Chassis
132
2. Click the Manage button in the application.
A. Run hardware scan button
B. Disk icons
C. Status line
3. Pull the failed drive out of the chassis and install a replacement without turning off the
server. The top drive is labelled Port 0, and the bottom drive is labelled Port 1.
Once the drive is installed, use the Intel Rapid Storage Technology application to initiate the
rebuild operation as described in the following steps.
4. Click the Run hardware scan button (identified as A in the above illustration) to refresh the
RAID data to the current state.
5. The volume icon has two smaller disk icons attached to it - one for each disk of the RAID
set. Perform one of the following operations:
- If the disk has previously been part of the RAID set, the disk appears as an icon attached
to the Volume 0 icon and the application immediately begins the rebuild. You can
monitor the status, in this case the status line displays “Rebuilding x% complete.
- If the replacement disk has never been part of this RAID set, the disk icons display a list
of available disks. The Status line will display “Degraded,” and the words “rebuild to
another disk” is underlined. Click on the underlined text.
AA
B
B
CC