Product specifications

AirSpeed 5000 Server Hardware Upgrade Checklist
158
3. Using the supplied set screws and a #2 Phillips head screwdriver, do the following:
a. Align the holes in the codec to the standoffs on the Video I/O board
b. Firmly attach the first codec to the connector on the Video I/O board.
n
Codecs can only be placed one way.
c. (Option: For 4-channel model servers only) Repeat Step 3 for the second codec.
4. (Option: For 4-channel model servers only) Locate Video I/O board #2 (VIO 2), and place it
component side up (with the standoffs showing).
5. Using the supplied set screws and a #2 Phillips head screwdriver, do the following:
a. Align the holes in the codec to the standoffs on the Video I/O board
b. Firmly, attach the first codec to the connector on the Video I/O board.
n
Codecs can only be placed one way.
c. (Option: For 4-channel model servers only) Repeat Step 5 for the second codec.
When both codecs are screwed down to the Video I/O board, it will look like this:
6. The next step is to replace the Video I/O board(s) (with the new codec modules installed)
back into the server.
Codecs secured to Video I/O Board