Warning: any changes to this equipment without permission may cause damages to your equipment! This equipment has been proved to can be prevented from the influence of harmful electronic jamming in normal business use condition. IMPORTANT NOTICE 1. IP MOTOR 9203 is deigned on the fundamental principle of learning in kit. 2. IP MOTOR 9203 is deigned to be used in-door, we have no responsibility for the possible damage in out-door use especially in the rain. 3.
AVIOSYS INTERNATIONAL INC WWW.AVIOSYS.COM. IP MOTOR 9203 USER MANUAL Table of Content 1. INTRODUCTION .......................................................................................................................... 4 FEATURES:........................................................................................................................................ 2. BEFORE YOU START ................................................................................................................
1. Introduction Imaging when you at office, you can control the movement of mechanism through the network at the far end, such as opening or closing the doors, windows, curtains, the rotation direction and speed of advertisement exposition mechanism – Post Sign or Neon Lighting, the sound volume of broadcast system. Web browsing becomes a daily habit of people. With IP MOTOR 9203, you can control any rotary mechanism by using any PC connected to the network from the far site.
AVIOSYS INTERNATIONAL INC WWW.AVIOSYS.COM. IP MOTOR 9203 USER MANUAL 2. Before you start 9203 package contents A set of IP MOTOR 9203 ( 9200 Module + 9203 Module) + RJ 45 network wire An adaptor with 1A, 12V output One D-Sub 15 Pin cable One two phases stepper motor. Install disc (include rapid instillation manual) Minimum System Requirements Minimum Intel Pentium II 300MHz/compatible AMD processor WINDOWS operating system (IE5.
3. Interface Description IP MOTOR 9203 has two modules – 9200 Module and 9203 Module, 1. 9200 is the network module, and the followed picture shows its interface: A︰D-SUB jack – connect 9203 B︰RJ45 jack C︰Reset button D︰Power LED light E︰Signal LED light 2. 9203 is the output module for motor and figure below shows its interface: A︰D-Sub connector ( connect 9200 module ) B︰12V Power jack C︰2 Axis stepper motor with 5 wire connectors.
AVIOSYS INTERNATIONAL INC WWW.AVIOSYS.COM. IP MOTOR 9203 USER MANUAL 4. Hardware & Software installation Before you start to use IP MOTOR 9203, please follow the steps below: Check the package to make sure the contents is complete. prepare one Ethernet HUB, or Router Check the voltage of the power supply to make sure it is AC 110-240 volt. Hardware Installation 1. Connect the 9200 to HUB through network wire 2. Connect the 9200 to 9203 through D-SUB cable by black jack.
3. Connect the stepper motor to the 9203( the line of stepper motor is ︰RED–A, Yellow– A', Orange–B , Blue–B', Pink–COM ) 4. Connect the 12V power adapter with the 9203 and confirm if each signal is correct . 9200 Module : A–Power light always on . B–Signal light all off then all on. 9203 Module : C–Signal light all on then all off。 Note: If the signal is not correct ,please press RESET bottom on the 9200 module and restart .
AVIOSYS INTERNATIONAL INC WWW.AVIOSYS.COM. IP MOTOR 9203 USER MANUAL 1. For 2 axis stepper motor: Working in 2 phase condition. The Working voltage is no more than 12V and axis currency no more than 1A.. 2. The 5 lines sequence is ︰ A phase、A'phase 、B phase 、B'phase 、COM。 3.
5. Initial Settings Initial setting through the Ethernet 1. Double click the EditV3.exe IPEditV3 可修改Name / Gateway / IP / Netmask / HTTP Port1) 2. All the IP 9200 series, IP Kamera 9000 series/IP Video 9100 series in the same subnet of the Ethernet will be found and be display in the window by the software. The default name of IP MOTOR 9203 is IP MOTOR. . 2- 1 : Change Name : MAXIMUM 10 DIGIT 2-2 : After Change Gateway , IP, Netmask (xxx.xxx.xxx.0 ~ xxx.xxx.xxx.
AVIOSYS INTERNATIONAL INC WWW.AVIOSYS.COM. IP MOTOR 9203 USER MANUAL 4. Double click the name of the equipment you want to control, the IE browser window will open and connected to this equipment in that Ethernet automatically. You also can type the IP address of the 9203 in the IE browser to open the web page of 9203. We suggest you to update the IE to version 6.0 with SP1 or higher if your IE notices you the security level is too low to open that web page. NOTICE: 1.
6. Control and settings through the Internet Explore Type the IP address of IP MOTOR 9203 in the IE address field and you can enter the login web page. Input the default password 12345678(you can change the password as you wish), click the OK and then you can enter the WebControl page. Web control operation of IP MOTOR 9203 1. Control the rotation of motor Fill the blank with proper number, and click apply button.
AVIOSYS INTERNATIONAL INC WWW.AVIOSYS.COM. IP MOTOR 9203 USER MANUAL angle every 0.05 second. If you fill in it with number 2, it means the stepper motor run a rotation angle every 0.02 second. * Selecting Left or Right in the Direct blank, you can choose the rotation direction. * Click “Apply” after the parameter setting finish , the motor will start rotating 。 2. Stop the unfinished rotation task Having finished setting the parameter and click apply button, the stepper motor will start running.
Setting the IP address for 9203 1. Setting a fixed IP address for IP Power 9202. Click the setup option in the left side of the window and you can enter the setting web page. Then follow the instructions fill in the new IP address, mask, and gateway for IP Sensor 9201, disable the DHCP service, click the submit button to confirm. Notice: 1)The format of IP Address : xxx.xxx.xxx.xxx: yyyyy,the port range of yyyyy is 1~32767。 2) The range of Subnet Mask is xxx.xxx.xxx.0 ~ xxx.xxx.xxx.
AVIOSYS INTERNATIONAL INC WWW.AVIOSYS.COM. IP MOTOR 9203 USER MANUAL Special Hardware Inter-Control - 92XX series : Use 9201 / 9212 ( DI part) to control ( IP Power 9212 & 9202 / IP Sensor 9201 / IP Motor 9203 ) 1.
2. Connect Client setup : A. Divide : this device word separate ly and do not use Inter-Control B. Light : This device can control 9202 / 9212 (IP Power) - by change the default setting of : Normal close or normal open C. Motor : This device can control 9203(IP Motor) –control the tdirection of turning.. 3. Controlled IP Address: Setting the Ip Address of controlled device . In Inter - control mode when transfer , . the Out Light(P6.1/P6.2) will always on ,if the maincontroller freeze the Out Light P6.
AVIOSYS INTERNATIONAL INC WWW.AVIOSYS.COM. IP MOTOR 9203 USER MANUAL Software online update : For wild application in different filed , IP POWER 9212 support online update .It safe time and money as developing your product .
7. Control the 9203 through SDK You can control the 9203 through the web page, and you can also control the rotation of 9203 by program. You can announce and quote the functions provide by us in VB or VC, associate it to the other equipment to build your own control system.
AVIOSYS INTERNATIONAL INC WWW.AVIOSYS.COM. IP MOTOR 9203 USER MANUAL 8. Setting the IP MOTOR 9203 through the Internet After you have setting the Ethernet and router properly, you can access the IP MOTOR 9203 from the Internet. It will bring you all kinds of convenience. Distribute different IP address to 9203, mapped it to the port of router, you can visit 9203 in the Ethernet from the Internet network. CUSTOMER HOTLINE: 886-2 –2959-2072. - 19 - VER. 1.
9. Associate the IP MOTOR 9203 with other IP network product You can associate the IP MOTOR 9203 with other IP network product of AVIOSYS in your home Ethernet, such as IP Kamera 9000 network camera, IP Video 9100 network video server and IP Sensor 9201, to monitor the equipments or sensors installed in the doors or windows. This is an economic solution to achieve the network monitor, detection and control.
AVIOSYS INTERNATIONAL INC WWW.AVIOSYS.COM. IP MOTOR 9203 USER MANUAL 10. FAQ Q1: I forgot the password and can not enter the administration page now, what can I do? A1: Turn on the power normally, and then click the ipedit.exe program to enter the web page. Type in the username “superuser” and then press the reset button in 9200; it will back to the default settings. Now you can enter the administration page.