6. Control and settings through the Internet Explore
Type the IP address of IP MOTOR 9203 in the IE address field and you can enter the login web
page. Input the default password 12345678(you can change the password as you wish), click the
OK and then you can enter the WebControl page.
Web control operation of IP MOTOR 9203
1. Control the rotation of motor
Fill the blank with proper number, and click apply button. IP MOTOR 9203 can control three
parameters of stepper motor: left/right rotation, rotation step, rotation speed.
* Filling in the STEP blank with proper number, you can control the rotation step of stepper motor.
Total rotation angles = rotation step×step angle of stepper motor
( The step angle of our stepper motor is 7.5° )
NoteIf you fill in it with number 0, it means the stepper motor
will have been kept rotating
all the time.
* Filling in the TIMER blank with proper number, you can control the speed of rotation. The unit of
TIMER is 0.01 second. If you fill in it with number 5, it means the stepper motor run a rotation
- 12 -