Installation guide

VisionPRO
®
TH8110 / TH8320 / TH8321
9
0500
0510
0520
0530
0540
0580
0600
0610
0640
0650
0660
0670
0680
0690
0700
0710
Furnace filter
change reminder
Humidifier pad
change reminder
UV lamp change
reminder
Adaptive Intelligent
Recovery
Program periods
Compressor
protection
Heat temperature
range stop
Cool temperature
range stop
Clock format
Extended fan
timer (heat)
Extended fan
timer (cool)
Keypad lock
Heat temperature
control
Cool temperature
control
Temperature
display offset
RESET
0Off
1 10-day run time (about 1 month)
2 30-day run time (about 3 months)
3 60-day run time (about 6 months)
4 90-day run time (about 9 months)
5 120-day run time (about 1 year)
6 365-day run time (about 3 years)
0Off
1 90 calendar days
2 180 calendar days
3 365 calendar days
0Off
1 365 calendar days
1 On ** See page 11
0Off
4 4 program periods (Wake, Leave, Return, Sleep)
2 2 program periods (Wake, Sleep)
5 5 minute compressor off time ** See page 11
[Other options: 0, 1, 2, 3 or 4-minute off time]
90 Max. heat temperature setting is 90°F (32°C)
[Other options: 40-89°F (4°C to 32°C)]
50 Min. cool temperature setting is 50°F (10°C)
[Other options: 51-99°F (11°C to 37°C)]
12 12-hour time (i.e., “3:30 pm”)
24 24-hour time (i.e., “15:30”)
0Off
90 Fan runs for 90 seconds after call for heat ends
0Off
90 Fan runs for 90 seconds after call for cooling ends
0 Keypad unlocked (fully functional)
1 Partially locked (access to temperature settings only)
2 Fully locked
2 Standard temperature control (recommended)
1 Choose if room does not reach heat setting after recovery
3 Choose if room is warmer than heat setting after recovery
2 Standard temperature control (recommended)
1 Choose if room does not reach cool setting after recovery
3 Choose if room is cooler than heat setting after recovery
0 Thermostat displays actual room temperature
[Other options: -3, -2, -1, 1, 2, 3°F offset (-1.5°C to 1.5°C)
0 No reset
1 Reset installer options & program schedule to factory
default (only date and time settings are retained)
Installer setup
Setup functions Settings & Options (factory default in bold)