User Manual

151.604UK User Manual
DMX operation
Whenever a DMX signal is present, this will take priority over auto and sound activated modes.
LED mode allows the standby default to be set when no DMX signal is present.
When this is set to on, the unit will revert to sound activated mode when no DMX is present.
When this is set to off, the unit will blackout when no DMX is present.
Temperature control
The VL-65 is fitted with a vari-speed cooling fan for quiet and efficient operation.
Up to 35°C = Fans off
35°C - 55°C = Fans low speed
Above 55°C = Fans high speed
In addition to the fan cooling, there is an LED output control for additional protection.
If temperature increases above 55°C, output will be decreased by 5% per degree up to 68°C.
If temperature exceeds 68°C, LEDs will shut down until temperature returns to below 60°C
Specifications
Power supply
100-240Vac 50/60Hz (IEC)
Power consumption
100W
Operating modes
Auto, Sound activated, Master/Slave, DMX
DMX operation
DMX512 - 2, 3, 3, 4, 5 or 8-channel
LED sources
6 x RGBWA 15W LED
Connection
DMX in/out (XLR), Mains in/out (IEC)
Dimensions
220 x 210 x 90mm (inc. bracket)
Weight
3.92kg
Troubleshooting
No power
No light output
No sound activation
Unresponsive to
DMX
Overheating/
cutting out