Remote Data Collection Device Product Manual

Documentation Number DCDSS11702 Manual Appendix A 3
B&B Electronics Mfg Co 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104
B&B Electronics Ltd Westlink Comm. Pk Oranmore, Galway, Ireland Ph +353 91-792444 Fax +353 91-792445
Buffer-Based Trigger
The buffer-based trigger automatically dials the modem after the
data buffer is a determined percentage full. The range is from 10%
to 80% in 5% increments. Keeping the buffer trigger below 100%
capacity allows for additional data to be stored while the connection
is being made.
Digital Input Trigger
The digital input trigger dials the modem when an input signal is
detected on the DCDSS1 digital input. It is a +5 volt signal, which
can be set to active high or active low. The signal must stay active
for at least 5 milliseconds to be detected.
Data Delivery Methods
Data and error logs can be emailed using a MIME attachment or
sent using FTP. Additionally, notifications can be configured to allow
email or pager notification that data has been delivered.
Error Conditions
The DCDSS1 has a 2.9 Kbyte error log buffer for storing error
conditions. Each error condition is time stamped.
Error Condition Logged Cause
BYTE(S) LOST
Data received from the local serial
port during ISP communications or
when in Bypass Mode is not stored
DATA OVERRUN Onboard UART FIFO overflowed
DATA ERROR
Character received with parity,
framing or break error
NOTIFICATION FAILED
An error occurred in the email
notification process (mail server
connection, command structure,
etc.)
DATA ATTACHMENT FAILED
An error occurred in the email data
process (mail server connection,
command structure, etc.)
ERROR ATTACHMENT
FAILED
An error occurred in the email error
log process (mail server connection,
command structure, etc.)
FTP FAILED
An error occurred in the FTP
process
(
FTP server connection,