Datasheet

EIRx-Sx series-0106 - 1/2
International Headquarters: 707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA
815-433-5100 Fax 433-5104 www.bb-elec.com orders@bb-elec.com support@bb-elec.com
European Headquarters: Westlink Commercial Park Oranmore Co. Galway Ireland
+353 91 792444 Fax +353 91 792445
www.bb-europe.com orders@bb-europe.com support@bb-europe.com
PRODUCT INFORMATION B&B ELECTRONICS
Hardened Compact
Media Converter
This quick installation guide describ d compact Media
Converter. Capable of operating at temperature
extremes of -34 to +74°C, this is the media converter
choice for harsh environments constrained by space.
100BaseFX Connections:
The Tx (transmit) port
of device 1 is connected to the Rx
(receive) port of device 2, and the
Rx (receive) port of device 1 to
the Tx (transmit) port of device 2.
Physical Description
Terminal Block and Power Inputs
10/100BaseTX and 100BaseFX Connectors
10/100BaseTX Connections:
Pin Regular Ports Uplink Port
1 Receive Data + (input) Transmit Data + (output)
2 Receive Data – (input) Transmit Data – (output)
3 Transmit Data + (output) Receive Data + (input)
4 NC NC
5 NC NC
6 Transmit Data – (output) Receive Data – (input)
7 NC NC
8 NC NC
LED’s and DIP Switch
LED Status:
LEDs State Indication
Steady Power or ports function abnormally FAULT
Off Power and ports function normally
Steady Power on (PWR stands for POWER) PWR1
PWR2
Off Power off
Steady 100Mbps network connection 10/100
Off 10Mbps network connection
Steady LFPT function enabled LFP
Off LFPT function disabled
Steady Network connection established(LNK stands for LINK)
Flashing Transmitting or receiving data(ACT stands for ACTIVITY)
LNK/ACT
Off Neither a network connection established nor
transmitting/receiving data
Steady Connection in full duplex mode(FDX stands for FULL-DUPLEX)
Flashing Collision occurred(COL stands for COLLISION)
FDX/COL
Off Connection in half-duplex mode
DIP Switch Settings:
Pos. Down(0) Up(1)
1 Disable Link-fault-pass-through Enable Link-fault-pass-through
2 RJ45 Auto Negotiation Enabled RJ45 Forced Mode
3 RJ45 Forced to 100Mbps RJ45 Forced to 10Mbps
4 RJ45 Forced to Full Duplex RJ45 Forced to Half Duplex
5 Fiber Forced to Full Duplex Fiber Forced to Half Duplex
6 Disable Link Down Alarm Enable Link Down Alarm
This quick installation guide describes how to install and
use the hardened compact Media Converter. Capable of
operating at temperature extremes of -34 to +74°C, this
is the media converter of choice for harsh environments
constrained by space.
Terminal Block Assignment
PWR1 Power Input 1 (10 to 48VDC)
GND Power Ground
PWR2 Power Input 2 (10 to 48VDC)
GND Power Ground
Earth Ground
FAULT
1. The relay opens if PWR1 or PWR2 fails
2. The relay opens if the Port Link is Down
(When the Link Down Alarm is Enabled)
While only one power source is
required to power up the media
converter, two power sources offer
redundancy for those mission critical
applications. (PWR1 and PWR2)
The terminals labeled Fault are
connected to a dry contact. The dry
contact is normally closed when either
power source is connected and active.
When no power is applied, the dry
contact is normally open.