User Guide

HDV100A3 Command & Response Manual-1306cr 27
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5104
Error Codes
Error Code Format:
Byte Number Byte Value Function
1 01 Start of frame
2 03 Number of control bytes
3 05 Function code error = 05
4 XY ID of message that caused error
5 0Z Error code (see chart below)
6 00 Number of data bytes
7 CS Checksum
Error Code Type of Error
Generated
Meaning of Error Generated
DEC HEX
1 1 Gen Inbuffer overflow; more than 127 bytes
2 2 Gen Checksum mismatch
3 3 Gen Protocol error; function, ID, code bad
4 4 J1708 J1708 input buffer full missed bus message
5 5 J1708 J1708 command unknown
6 6 J1708 J1708 output buffer full
7 7
8 8 J1939 Bus off
9 9
10 A J1708 J1708 inbuffer overflow more than 127 bytes
11 B
12 C
13 D
14 E
15 F