User Guide

HDV100A3 Command & Response Manual-1306cr 3
B&B Electronics -- 707 Dayton Rd. -- PO Box 1040 -- Ottawa, IL 61350
PH (815) 433-5100 -- FAX (815) 433-5104
Formatting the Control Bytes
The 2
nd
byte is “Number of Control Bytes” to follow and always
precedes the control field. The third byte is the ID byte. This byte tells the
hardware where to direct the message. Valid entries for functions are:
ID Codes
=01 Message for J1708
=02 Message for J1939
=08 General message (for control of the HDV100A3 device)
=05 Device identification (reverse compatible)
The fourth byte is the function byte. The functions that are
supported are listed below. Note that some of the function codes are
followed by additional bytes of information. These bytes must be included in
the control byte count.
Valid General Function Codes
Function codes
=01 change PC baud rate, followed by 3 bytes (UB3, Baud1, Baud2)
=02 send time stamp
=04 hardware handshaking
=08 reset converter, followed by 2 bytes (01,and 02)
=10 time stamp off
=20 time stamp on
Valid Entries for J1708 Functions
Function codes = 07 set broadcast message
= X8 set filter X off
= X9 set filter X on
= 11 Sync with J1708 bus and start reception
= 10 Stop reception
= 12 Transmit to J1708 bus
Valid Entries for J1939 Functions
Function codes =00 Receive off
=01 Receive on
=02 Transmit message
=08 Set mask
=X8 set filter X off
=X9 set filter X on