User Manual

130
7. Press the key to return to the DECODE menu.
8. Press the Configure softkey to enter the BUS CONFIG menu.
Figure 120 - DECODE CONFIG menu
9. Press the Baud softkey and turn the Universal Knob to select the baud rate that matches your
CAN bus signal. The CAN baud rate can be set to predefined baud rates from 5 kb/s up to 1
Mb/s or a custom baud rate from 1 b/s to 1 Mb/s. If the desired baud rate is not listed, select
Custom on the Baud softkey. Press the Custom softkey and turn the Universal Knob to set
the desired baud rate.
10. Press the Decode Source softkey to set the decoding matching source:
CAN_H: The actual CAN_H differential bus.
CAN_L: The actual CAN_L differential bus signal.
CAN_H-CAN_L: The CAN differential bus signals connected to an analog source channel
using a differential probe. Connect the probe's positive lead to the dominant-high CAN
signal (CAN_H) and connect the negative lead to the dominant-low CAN signal (CAN_L).
CAN Serial Decode
To set up CAN serial decode, follow these steps:
1. Press the Decode button to display the DECODE menu.
2. Press the Display softkey and choose On to display the decode line on the display.
3. Press the List softkey to enter the LIST menu.
4. Press the Display softkey and choose Decode 1 or Decode 2 to display the decode list on the
display. You can also select Off.
5. Press the Scroll and Lines softkeys to set the position of the cursor and the line number of
the list with the Universal Knob. The range of Lines is 1 to 7.
The picture below triggers on ID, the ID is 0x013