Specifications

Halogen Gas Monitor – MultiZone Remote Display
Instruction 3015-5157 35
Alarm Detail Screen
To further investigate an alarm, select the alarm on the Alarm Summary screen, then press ENTER to access
the Alarm Detail Screen.
Alarm Detail Screen
The Alarm Detail Screen displays more comprehensive information about the nature of the alarm including:
Complete location information
Refrigerant and current PPM
Peak PPM and peak time
Type of alarm, alarm time, and date
This screen provides the following three options at the bottom of the display:
ACK (<<) Acknowledges the alarm as described in the next section
ESC Returns you to the Alarm Summary Screen
SETUP (>>) Takes you to Zone Setup Screen #1 (Page 27), which enables you to review the zone
setup parameters and access the Trend Screen