Datasheet

94
Technical characteristics
Characteristics
Standards
Data
>
Storage temperature
-4C
to
+7C
>
Operating temperature
-2C
to
+7C
>
Climatic resistance Constant humid heat
IEC 60068-2-3
Cyclic damp heat
IEC 60068-2-30
Resistance to sea air
IEC 60068-2-52
>
Degree of protection IP 66 for standard heads
IEC 60529
IP 67 for shrouded heads
IP 66 for equipped control stations
IP 20 at the rear of the panel for contact blocks
a
nd one piece pilot lights
Type 1, 2, 3, 3R, 3S, 4, 4X, 12, and 13 for heads and control stations NEMA standard
>
Protection against mechanical impacts IK 05 illuminated and non illuminated heads
IEC 62262
IK 07 empty control station
>
Electrical insulation Class II - heads and control station
IEC 60947-5-1
>
Terminal marking
IEC 60947-1
>
Tightening torques Locking ring: recommended 3 N.m
terminals: max. 1.2 N.m
>
Approvals UL United states and Canada
UL 508, CSA 22.2
BV Bureau Véritas Marine rules
Certification OC/CB
IEC 60947-5-1
IEC 60947-5-5
IEC 60947-5-4
>
Vibrations withstand vibration
IEC 60068-2-6
Fc test:2to 25 Hz, 1.6 mm;25-100Hz,4g