Electric Company Water Heater User Manual

2-12 Installation & Operation MN1800
LMPY Series Continued
Polynoid Linear Motor Holding Option Continued
Operation Considerations The motor must always be operated within the specified operating parameter limits.
Exceeding those limits will permanently damage the motor.
Note: Rod should not support axial loads that can induce premature bearing failure.
The following steps must be completed to ensure safe and proper operation.
1. Verify that all electrical wiring and cables are properly connected. Refer to the
manual provided with the control for this information.
2. If using a control, adjust the control continuous current limit to match the
motors continuous current specifications.
3. Adjust the control peak current limit so it will not exceed the motors peak
current specification.
Leadwire Connection
Motor Cable
Signal Name Wire Color
Motor Phase A Black
Motor Phase B Red
Motor Phase C White
Mounting Instructions Refer to the outline drawing (supplied with motor) for hole dimensions and mounting
information. When attaching the payload to the motor, avoid axial loading of the motor
shaft. Axial loading can damage the rulon bearing.