AY1801A00 Stages with Renishaw Encoder (RGH22) Flying Leads
Cable 1
(Hall Cable)
Cable 2
(Motor Cable)
Cable 4
(RGH22
Encoder Cable)
Cable 3
Limit Cable
(optional)
Cable
1
1
1
1
1
1
1
2
2
2
2
2
2
2
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
Conductor
A
B
C
D
E
F
G
A
B
C
D
E
F
G
A
B
C
D
E
F
A
B
C
D
E
F
G
H
I
J
Signal Name
Hall 3 (C)
Hall 2 (B)
N/C
Hall Ground
Hall 1 (A)
Voltage IN (+5VDC)
Shield
Motor Phase A (U)
Motor Phase B (V)
Motor Phase C (W)
Motor Ground
Thermal Switch +
Thermal Switch -
Shield
Limit/Home Ground
Home Output
Limit + Output
Shield
Limit & Home PWR *
Limit - Output
Signal A+
Signal A-
Signal B+
Signal B-
Signal C+
Signal C-
+5VDC
0VDC
Outer Shield
Inner Shield
Color
Black
Red
N/C
Blue, Green or Yellow
White
Brown or Violet
Red
White
Black
Green
Orange
Blue
Blue, Green or Yellow
Black
White
Brown
Red
Green
Yellow
Blue
Red
Violet
Gray
Brown
White
* Limit & Home power is +4 to +24VDC.
10 ft cable for use with Renishaw RGH24.
Flying leads are color coded as shown in this diagram.
Note: Motor phasing is for LinDrive or MintDrive. Other controls may require different phasing (such as most trap
drives (U) Black, (V) Red, (W) White). Phase angle between phases is 120 degrees.
AY1802A00 Stages with Renishaw Encoder (RSF) Flying Leads
Cable 1
(Hall Cable)
Cable 2
(Motor Cable)
Cable 4
(MS6X
Encoder Cable)
Cable 3
Limit Cable
(optional)
Cable
1
1
1
1
1
1
1
2
2
2
2
2
2
2
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
Conductor
A
B
C
D
E
F
G
A
B
C
D
E
F
G
A
B
C
D
E
F
A
B
C
D
E
F
G
H
I
J
Signal Name
Hall 3 (C)
Hall 2 (B)
N/C
Hall Ground
Hall 1 (A)
Voltage IN (+5VDC)
Shield
Motor Phase A (U)
Motor Phase B (V)
Motor Phase C (W)
Motor Ground
Thermal Switch +
Thermal Switch -
Shield
Limit/Home Ground
Home Output
Limit + Output
Shield
Limit & Home PWR *
Limit - Output
Signal A+
Signal A-
Signal B+
Signal B-
Signal C+
Signal C-
+5VDC
0VDC
Limit +
Limit -
Color
Black
Red
N/C
Blue, Green or Yellow
White
Brown or Violet
Red
White
Black
Green
Orange
Blue
Blue, Green or Yellow
Black
White
Brown
Red
Green
Yellow
Orange
Red
Blue
Violet
Black
Brown
Gray
White
* Limit & Home power is +4 to +24VDC.
10 ft cable for use with RSF.
Flying leads are color coded as shown in this diagram.
Note: Motor phasing is for LinDrive or MintDrive. Other controls may require different phasing (such as most trap
drives (U) Black, (V) Red, (W) White). Phase angle between phases is 120 degrees.