Electric Company Water Heater User Manual

Installation & Operation 2-27MN1800
AY1682A00 LSX Stage Endplate Internal Connections
* Limit & Home power is +4 to +24VDC.
A
B
C
D
E
F
G
H
J
K
L
M
N
P
R
S
T
U
V
19 Pin Circular Connector (Male)
1
2
3
4
5
11
12
13
14
15
Male (D Sub)
15 Pin D Sub (Male)
Color Pin# Description
Red A Motor Phase A (U)
White B Motor Phase B (V)
Black C Motor Phase C (W)
Green D Motor Ground
E Motor Shield
Blue F Thermal Switch +
Orange G Thermal Switch
M Limit Shield
White N Limit + Output
Red P Limit Output
Black R Home Output
Green S Limit & Home Ground
Brown T Limit & Home Power *
19 Pin Circular Connector (Male)
Color Pin# Description
Green 1 A+
Pink 2 B+
Brown 3 C+
White 4 Hall1
5 N/C
Yellow 6 A
Red 7 B
Gray 8 C
Black 9 Hall3
Red 10 Hall2
White 11 +5VDC
(Halls Brown)
12 N/C
Black 13 Encoder GND
(Halls Green)
14 Hall Shield
15 Encoder Shield
15 Pin D Sub (Male)
Note: Motor phasing is for LinDrive or MintDrive. Other
controls may require different phasing (such as
most trap drives (U) Black, (V) Red, (W) White).
Phase angle between phases is 120 degrees.
Encoder / Hall Connections
Motor / Limit Connections