Electric Company Water Heater User Manual

Installation & Operation 2-37MN1800
Mix 4 and Mix 5 Dial Settings
Dial Setting Resolution (using 4x multiplier)
1000 1000 µm/pulse (1mm) Note: These resolutions
are only available
with 4 edge
counting mode.
500 500 µm/pulse (0.5mm)
100 100 µm/pulse (0.1mm)
50 50 µm/pulse (0.05mm)
10 10 µm/pulse (0.01mm)
5 5 µm/pulse (0.005mm)
ELGO Mix 5 series Magnetic Type
Encoder type: Non contact, magnetic, open type. Open scale linear encoders are used
primarily where environmental conditions are clean, dry and free of oils. The magnetic
encoder scale is susceptible to damage from magnetic fields. Great care should be taken
to isolate the magnetic scale from magnets, static electricity, and electrical current.
Mechanical design: Magnetic scale with stainless steel protective cover, magnetic
sensor unit, high flex twisted shielded cable. The magnetic linear encoder system
features an integrated sensor and translator with a continuous marker pulse output. The
marker pulse is sent every time the sensor passes the marker tape (maximum speed 0.1
m/second). Encoder is bonded to the stage surface with a double sided industrial
adhesive tape. (DO NOT attempt to remove the scale from the stage surface, for this will
permanently damage the encoder scale. Contact Baldor or an authorized distributor for
assistance).
Maintenance: The encoder scale can be cleaned with soapy water or alcohol. Avoid
chemicals such as acetone, MEK, and other solvents. The encoder magnetic scanning
unit should be treated with great care as not to scratch or mar the external read head
surface. If cleaning is required, the encoder read head surface can be cleaned with
soapy water or alcohol. (Avoid submersion). Using a cotton swab, lightly wipe clean the
contaminated surfaces. If removal of the encoder magnetic read head is required,
consult with Baldor or an authorized distributor.
Wiring diagram: (for flying leads, high flex cable, 5.7mm diameter)
ML6004A00 5.7mm Diameter Cable
Color Description Function
White +5VDC Encoder Power
Black 0VDC Encoder GND
Green A+ Incremental Signal
Yellow A Incremental Signal
Pink B+ Incremental Signal
Red B Incremental Signal
Brown C+ Incremental Signal
Gray C Incremental Signal
Shield Shield (Connect to Earth Ground)
Technical Data:
Encoder Type: Quad digital output
Input power: 5VDC, 200mA
Output: A/B quadrature and reference marks, differential line drive output
Resolution: 5.0, 10.0 micron
Accuracy: Resolution dependent
Reference mark: Continuous (bidirectional)