Installation guide

Setup - Integration Protocol Settings
Integration Protocol
The Integration Protocol makes it possible for other devices to interact with BeoLink Gateway. The protocol is
used by mobile applications or by other home automation controllers. Integration protocol can be enabled on the
local network, as well as on the RS232 port.
Note!
To be able to use the BeoLink App the Integration Protocol must be enabled on the local network.
TCP port
For the LAN a TCP port must be allocated. The default port is 9000. Ports below 1024 are reserved for
standard TCP services.
Requires authentication - [Enable/disable]
Authentication is optional. Enabled is recommended to prevent unauthorized access to BeoLink Gateway.
It could be necessary to disable the function if a controller connected to BeoLink Gateway does not support
authentication.
RS232 - via USB serial converter
*
If RS232 is used a bit rate must be selected.
- Options:
- Bit rates: 9600 bps
19200 bps
38400 bps
57600 pbs
115200 bps
When integration protocol over RS232 is active (TCP disabled) other devices will not be able to use this port. The
RS232 connection does not require authentication.
*USB to RS232 converter
The USB to RS232 converter, which is used for the B&O ServiceTool can be used.