97055 v.8.0 31
Figure 34 All Models Vacuum Solenoid Connection Location
8. Route the Wiring Harness along the
A.C. hose. Secure it later with cable
ties after you have confirmed there
is enough Harness to reach all the
needed connectors.
9. Locate the connector for the
Vacuum Solenoid on the Banks Wiring
Harness. Route the wire to Vacuum
Solenoid along the hose connected to
the Solenoid and plug in the connector
to the Solenoid as seen in Figure 34.
Secure the wire and vacuum hose to
the factory wiring harness with cable
ties.
10. Locate the transmission Intercept
Connectors on the Banks Brake Wiring
Harness and route to the driver’s side
of the transmission.
11. If installing kits 55225 & 55226,
Locate the factory C108 connector on
the driver side of the transmission.
Disconnect the C108 connector by
sliding the locking tab out and press
the locking clip while removing the
connector. Take the Banks C108
Intercept Harness and insert the Male
Connector into the female connector
on the C108 harness. Insert the
Female Connector on the Intercept
Harness onto the male connector of
the C108 harness. You should feel
and/or hear the connectors lock. Lock
the connectors by sliding the locking
tabs in. Secure the Harness away from
any heat sources and moving parts
with cable ties.