3.4 Connection Terminals and Functions
All electrical connections are made through removable terminals
(see Figures 3-4a and 3-4b).
To disable the SSI, terminal X5 (SSIb) must be jumpered to
terminal X6 (SSIa), and terminal X7 (SSId) must be jumpered to
terminal X8 (SSIc) (factory default). Do not short Channel A to
Channel B.
WARNING . . . Proper Electrical
Hookup
Electrical hookup must be made by Qualified
Personnel and must comply with NEC (National Electrical
Code) and local standards.
Make no connections to the System other than those
described in Section 3 of this manual. Doing so could result
in serious injury or death.
Figure 3-4a. MMD-TA-11B terminal connection locations
A1 X1 X2
S11 S12 S21 S22
Z21 M1 Z11
X5 X6 X7 X8
Z12 M2 Z22
Z13 M3 Z23
Z14 M4 Z24 X13 X14 A2
X9 X10 X11
X12
Y1 Y2 Y3 Y4 X3 X4 Z3 Z4 Y5 Y6 Y7
Y8
Terminal Function Terminal Function Terminal Function
Z13 M3, 0V Z21 M1, 24V Z12 M2, 0V
M3 Muting 3 In (PNP) M1 Muting 1 In (PNP) M2 Muting 2 In (NPN)
Z23 M3, 24V Z11 M1, 0V Z22 M2, 24V
S11 MSSI b (ch A) X5 SSI b (ch A) X9
Override a
(ch A)*
S12 MSSI a (ch A) X6 SSI a (ch A) X10
Override b
(ch A)*
S21 MSSI d (ch B) X7 SSI d (ch B) X11
Override c
(ch B)*
S22 MSSI c (ch B) X8 SSI c (ch B) X12
Override d
(ch B)*
Y1 EDM 1 a Out (24V) X3 Mute Lamp Out (24V) Y5 OSSD 1 a Out
Y2 EDM 1 b In X4 Mute Lamp In Y6 OSSD 1 b 0V
Y3 EDM 2 b In Z3 AUX b 0V Y7 OSSD 2 b 0V
Y4 EDM 2 a Out (24V) Z4 AUX a Out Y8 OSSD 2 a Out
A1 +24V dc Z14 M4, 0V X13 Mute Enable Out (24V)
X1 Reset In M4 Muting 4 In (NPN) X14 Mute Enable In
X2 Reset Out (24V) Z24 M4, 24V A2 0V dc
All terminals are low-voltage
Figure 3-4b. MMD-TA-12B terminal connection locations
*contacts only
Potential
High-Voltage
Terminals
A1 X1 X2
S11 S12 S21 S22
Z21 M1 Z11
X5 X6 X7 X8
Z12 M2 Z22
Z13 M3 Z23
Z14 M4 Z24 X13 X14 A2
X9 X10 X11
X12
Y1 Y2 Y3 Y4 X3 X4 31 32 13 14 23
24
All terminals are low-voltage,
except for those indicated
otherwise
Terminal Function Terminal Function Terminal Function
Z13 M3, 0V Z21 M1, 24V Z12 M2, 0V
M3 Muting 3 In (PNP) M1 Muting 1 In (PNP) M2 Muting 2 In (NPN)
Z23 M3, 24V Z11 M1, 0V Z22 M2, 24V
S11 MSSI b (ch A) X5 SSI b (ch A) X9
Override a (ch A)*
S12 MSSI a (ch A) X6 SSI a (ch A) X10
Override b (ch A)*
S21 MSSI d (ch B) X7 SSI d (ch B) X11
Override c
(ch B)*
S22 MSSI c (ch B) X8 SSI c (ch B) X12
Override d
(ch B)*
Y1 EDM 1 a Out (24V) X3 Mute Lamp Out (24V) 13 OSSD 1 a (Relay)
Y2 EDM 1 b In X4 Mute Lamp In 14 OSSD 1 b (Relay)
Y3 EDM 2 b In 31 AUX a (Relay) 23 OSSD 2 a (Relay)
Y4 EDM 2 a Out (24V) 32 AUX b (Relay) 24 OSSD 2 b (Relay)
A1 +24V dc Z14 M4, 0V X13 Mute Enable Out (24V)
X1 Reset In M4 Muting 4 In (NPN) X14 Mute Enable In
X2 Reset Out (24V) Z24 M4, 24V A2 0V dc
*contacts only