Manual

38 P/N 116390 rev. C
Banner Engineering Corp. Minneapolis, U.S.A.
www.bannerengineering.com Tel: 763.544.3164
MMD-TA-11B / MMD-TA-12B Muting Module
Instruction Manual
System Installation
Figure 3-27. Generic machine interface hookup, model
MMD-TA-11B: MPCE with 2-channel EDM
Figure 3-28. Generic machine interface hookup, model
MMD-TA-11B: MPCE with 1-channel EDM
A1
+24V dc 0V dc
EDM1
EDM2
L2L1
K1A K2A
K1B
K1C
K2B
K2C
MMD-TA-11B
A2
Y1
Y2
Y3
Y4
32
23
24
31
14
MPCE1
13
Machine
Control
Circuits
MPCE2
A1
+24V dc 0V dc
EDM1
EDM2
L2L1
K1A K2A
K1B
K1C
K2B
K2C
MMD-TA-11B
A2
Y1
Y2
Y3
Y4
32
23
24
31
14
MPCE1
13
Machine
Control
Circuits
MPCE2
WARNING . . . Proper Wiring
The generalized wiring configurations shown
are provided only to illustrate the importance of
proper installation. The proper wiring of the Muting Module to
any particular machine is solely the responsibility of the
installer and end user.
CAUTION . . . Shock Hazard
Always disconnect all power from the Muting
Module and the guarded machine before
making any connections or replacing any component.
Use extreme caution to avoid electrical shock at all times.
Serious bodily injury or death could result.
WARNING . . . Use of Transient
Suppressors
Transient suppressors are recommended.
They MUST be installed across the coils of the machine
control elements. NEVER install suppressors directly
across the outputs of the Module! It is possible for
suppressors to fail as a short circuit. If installed directly
across the contacts of the Module, a short-circuited
suppressor will create an unsafe condition.