Specification

Safety Information
1. To reduce the risk of electric shock, the electricity has been turned off at the circuit
breaker or fuse box before begin.
2. All wiring must be in accordance with the National Electrical Code NASI/NEPA 70-1999
and local electrical codes.Electrical installation should be performed by a qualified
licensed electrician.
3. The outlet box and support structure must be securely mounted and capable of
reliably supporting 35lbs. (15.9kg). Use only UL listed outlet boxes marked “Acceptable
for Fan Support of 35lbs(15.9kg) or less."
4. The fan must be mounted with a minimum of 7 ft. (2m) clearance from the trailing
edge of the blades to the floor.
5. Do not operate the reversing switch while the fan blades are in motion. You must turn
the fan off and stop the blades before you reverse the blade direction.
6. Do not place objects in the path of the blades.
7. To avoid personal injury or damage to the fan and other items, please be careful
when working around or cleaning the fan.
8. Electrical diagrams are for reference only. Light kits that are not packed with the fan
must be UL -listed and marked suitable for use with the model fan you are
installing.Switches must be UL General Use Switches. Refer to the instructions packaged
with the light kits and switches for proper assembly.
9. After making electrical connections , spliced conductors should be turned upward and
pushed carefully up into the outlet box.The wires should be spread apart with the
grounded conductor and the equipment-grounding conductor on one side of the outiet
box.
10. All set screws must be checked and retightened where necessary before installation.
02