User manual

ENGLISCH
Manual
For
LEDcontroller
Set controlled white
Item no. 66000019 Set Controller with remote
Please read carefully and keep for further information
1. Use as directed:
This product serves exclusively lighting purposes and may:
- only be used in dry condition,
- not in damp or dirt-endangered rooms.
- not in areas of high air humidity.
- not be exposed to strong mechanical loads or to strong
contamination.
- only be installed and operated after a condition inspection if the
product is dirty or has been moistened through storage.
- not be modified or converted.
If these points named above are not adhered to, a short circuit or
electrical shock may occur!
2. Technical Data:
Controller:
Operating voltage: 12 / 24 V DC
Output: max. 2x6A
Power: max. 288W
Safety class: III
Measures (L/W/H): 83 / 79 / 33 mm
Remote:
Operating voltage: 4.5 V DC
Batteries: 3 * 1.5V Micro-cells (AAA/LR03)
Safety class: III
Measures (L/W/H): 114 / 56 / 23 mm
3. Installation
The electric wiring/connection must comply with all current and valid
national requirements, be constructed by a certified electrician, and,
comply with all the requirements set forth in this planning manual.
Attention: Disconnect the system and the device before beginning any
work!
Assembly site
The unit is suitable for installation on wall, ceiling and floor.
Make sure that the unit is mounted on a stable, plain, non-tilting base. In
operation the unit might produce heat. Adequate air ventilation must be
ensured.
4. Connection
Important: The module must be operated with a power supply that is suitable
for the used LEDs!
Improper power supplies may lead to malfunctions and unwanted flickering
effects or overheating.
The unit is equipped with a limited protection against reverse polarity.
Connecting the power in reverse polarity can destroy the module, even if
connected for a short time only.
Be sure to select the cables according to the current load (com+ max. 12A!)
Make sure before switching on, that all cables are properly connected. Note:
Consider min. 20% power reserve at continuous operation.
Wiring diagram:
5. Operation
:
Information for the user:
Please operate this unit only when it is working properly.
In case of an error, switch off the unit immediately. Do not operate the unit
until the unit was verified electronically by a qualified electrician.
A case of error is:
- Visible signs of damage on the unit
- The unit is not operating properly
- fume rising or crackling sounds from the unit
-Visible signs of overheating
Maintenance and service which require access to live components inside the
unit must be carried out by an authorized electrician.
Warning: risk of electric shock!
How to avoid malfunctions or fire risk:
-Do not affect air circulation by covering the unit.
- Do not attach anything to the unit e.g. decoration items etc.
- Do not let your children play unattended with electrical equipment. Children
cannot always perceive possible dangers correctly.
When using multiple devices for different color zones:
In the delivery status each controller can be controlled with any remote
control. This is a problem when multiple color zones to be used. It is possible
to bind a controller to an explicit remote control so that this controller only
responds to commands of this remote control.
How to realize the function of Match Code:
Open the iron shell cover, press down the “Match Code Button” on the
controller and press down the “Ibutton on the RF remote control at the same
time, wait for the LED lamp flashing several times, then move away from the
two buttons. Now the RF remote control and the controller have been
matched.
6. Usage
Symbol Function
Turn off / on
to quickly adjust get warm white or cool
white
adjust color temperature between warm
white and cool white
increase or reduce brightness
After 20 sec. of not using, the remote changes into standby mode to safe
battery power. Touch a key on the remote (not the adjustment color wheel) to
wake up the remote.
If the status LED blinks regularly without touching the remote control, please
replace the batteries.
7. What else has to be considered?
Disconnect the product from power, before you…
- clean or maintain the product.
- do any works on the product or its components (only authorized electrician)
Please remove and replace empty batteries because they could leak.
V1.3 02/2016 © by Barthelme
Oedenberger Str. 149
D-90491 Nürnberg, Germany
Technical Details are subject to change.
Cancel Match Code:
Press down the ”Match Code
Button“ on the controller and
press down the ”O” button on
the RF remote control at the
same time, wait for the LED
lamp flashing several times,
then move away from the
two buttons. Now the RF
remote control and the
controller have been
canceled Match Code.