6.3.2 Electrical connection
The electrical connection shall be carried out in accordance to the local laws in force.
The machine has a connection at the back, indicated by the symbol
, that is meant to
link the steel structure and masses among different apparatuses, to prevent electro-static
electrical shocks.
Theelectricalsupplycablemustbenew,exible,andaccordingto"har"H07RN-Foralocal
validequivalent.Thecablesizeisdimensionedaccordingtothepower.
ShouldtheelectricalsupplycablegetdamageditshallbechangedbytheManufacturer,orhis
AuthorizedService,orothertechnicianwithequivalentqualication,topreventanyrisk.
Ifthemachineisttedwithathree-phasepump,checkthecorrectmotorrotation(rightro-
tationasperarrowonthecasing).Thisisnotneededifthepumpisasingle-phasemodel
(standard).
6.3.3 Water connection
Connectthewaterin-feedhose,givenwiththemachine,toa¾”watersupplytap.
Connect the machine draining pipe to the connection located at rear, under the back-panel,
insuchawaythatwaterowsfreely(thereforeensuringaminimumslope).Ifthewater
cannot be discharged to a level below the machine drain, it is advisable to install a drain
pump(suppliedonrequest).
Maximumdrainheight=cm.50(seepict.7).
The drain tube shall always be connected to a siphon in order to prevent the release of
odors.
Inthosemachinesequippedwith“watersoftener”thewatersupplytemperatureshallnot
exceed40°C,toavoiddamagestothelters’resins.
6.3.4 Start-up
Atinstallationengineer’scare.
MAX 0,5m
pict. 7
2
3
1
pict. 6