1.4 Regeneration function (optional)
The machine can be supplied with the Regeneration function.
The frequency of the regeneration cycle is driven by the hardness of the water, as set on
parameter "3" (see chap. 1.9.5).
1.5 Pressure increase pump (optional)
The machine can be supplied with the pressure increase pump.
After periods of machine inactivity, make sure the supplementary pressure increase pump
rotates freely. To do this, operate by inserting a screwdriver in the special notch on the motor
shaft, ventilation side.
In case of blocking, move the motor shaft, inserting the screwdriver in the notch, turning it
clockwise and anticlockwise.
1.6 Rinse pump (only on PLUS version)
After periods of dishwasher inactivity, make sure the rinse pump rotates freely. To do this,
operate by inserting a screwdriver in the special notch on the motor shaft, ventilation side.
In case of blocking, move the motor shaft, inserting the screwdriver in the notch, turning it
clockwise and anticlockwise.
1.7 Additional Cooling Function (Optional)
The machine can be equipped with an additional cooling function, on request.
After the hot rinse is completed, an additional fresh-water rinse can be made.
1.8 Setting the Parameters
1.8.1 Control panel and relative symbols
A) Cycle light indicator
B) Selectedprogramindicators
C) Tank temperature display
D) Boiler temperature display
E)MachineONindicator
F) Regeneration indicator
G) Drain Pump indicator
H)STARTkeytostartupcycle/cycleselection
I) Cold rinse indicator
J)SwitchingON/OFF/STANDBY
K) Regeneration key (optional)
L) Drain Pump key
1.8.2 Functions of keys during programming
H) Programming/Input
J) Output
K) Decrease
L) Increase
pict. 3