User manual

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
© Copyright 2017 by Conrad Electronic SE. 1574789ff_V1_0917_02_VTP_m_en
Getting Started, Operation
Read and follow the chapter “Safety Instructions” carefully.
Completely unwind the cable of the outlet strip.
Plug the earthed mains plug of the power strip into a regular earthed mains socket (wall
socket).
Place the power strip in an appropriate place. Protect valuable furniture surfaces by using a
suitable underlay to prevent scratches. Place the cables in such a way that nobody can trip
over them.
Connect the consumer loads to the sockets of the outlet strip.
If the socket strip has an on/off switch (see chapter “Technical Data”), you can switch all
connected loads on or off. When the adapter is switched on, a control light in the on/off
switch is activated.
Socket Strip Item No. 1574789
This power strip has surge protection. The surge protection is ready when the red warning
light shines.
If the red warning light does not shine, the surge protection has tripped. In this case, the socket
strip may still be used, but surge protection is no longer provided.
The green control light indicates that the protective conductor is available (control light is
activated).
If the socket strip is connected to the mains voltage (and the mains voltage is availa-
ble), but the green control light does not shine, something is wrong with the voltage/
power supply. Unplug the mains plug of the socket strip from the mains socket.
Do not connect any device to the mains socket, but have it checked by an expert.
Maintenance and Care
The product is maintenance-free for you. The product contains no parts that require servi-
cing. Therefore, do not open/dismantle it. Maintenance or repair may only be performed by
Then unplug the socket strip from the mains socket (wall socket).
Use a clean, dry and soft cloth for cleaning.
Dust can easily be removed using a clean, soft, long-bristled brush and a vacuum cleaner.
Do not use abrasive cleaning agents, cleaning alcohol or other chemical solutions
since these could damage the housing or even impair operation.
Disposal
Electronic devices are recyclable material and do not belong in the household was-
te. Dispose of the product at the end of its service life in accordance with the relevant
statutory regulations.
Technical Data
See table to the right.
Item No. Electrical connection
data
Total electrical
supply
Protective con-
tact sockets
Mains socket with
child protection
On/off switch Surge protection Cable
length
Cable type Dimensions
(L x W x H)
Ambient tem-
perature
Ambient humidity
(relative, non-condensing)
1574789 250 V/AC, 50 Hz, 16 A 3680 W (max.) 6 yes yes (bipolar) yes (leakage current 9 kA) 1.4 m H05VV-F 3G1.5 mm² 365 x 48 x 52 mm -10 °C to +50 °C 10% to 90%
1593785 250 V/AC, 50 Hz, 16 A 3500 W (max.) 3 no no no 1.4 m H05VV-F 3G1.5 mm² 165 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593786 250 V/AC, 50 Hz, 16 A 3500 W (max.) 3 no no no 4.8 m H05VV-F 3G1.5 mm² 165 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593787 250 V/AC, 50 Hz, 16 A 3500 W (max.) 3 no no no 2.8 m H05VV-F 3G1.5 mm² 165 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593788 250 V/AC, 50 Hz, 16 A 3500 W (max.) 3 no no no 2.8 m H05VV-F 3G1.5 mm² 165 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593789 250 V/AC, 50 Hz, 16 A 3500 W (max.) 3 no yes (bipolar) no 1.4 m H05VV-F 3G1.5 mm² 190 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593790 250 V/AC, 50 Hz, 16 A 3500 W (max.) 3 no yes (bipolar) no 1.4 m H05VV-F 3G1.5 mm² 190 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593791 250 V/AC, 50 Hz, 16 A 3500 W (max.) 6 no no no 4.8 m H05VV-F 3G1.5 mm² 295 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593792 250 V/AC, 50 Hz, 16 A 3500 W (max.) 3 no no no 1.4 m H05VV-F 3G1.5 mm² 165 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593793 250 V/AC, 50 Hz, 16 A 3500 W (max.) 6 no no no 1.4 m H05VV-F 3G1.5 mm² 295 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593794 250 V/AC, 50 Hz, 16 A 3500 W (max.) 3 yes yes (bipolar) no 2.8 m H05VV-F 3G1.5 mm² 190 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593795 250 V/AC, 50 Hz, 16 A 3500 W (max.) 3 yes yes (bipolar) no 2.8 m H05VV-F 3G1.5 mm² 190 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593796 250 V/AC, 50 Hz, 16 A 3500 W (max.) 6 no no no 1.4 m H05VV-F 3G1.5 mm² 295 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593797 250 V/AC, 50 Hz, 16 A 3500 W (max.) 6 yes yes (bipolar) no 2.8 m H05VV-F 3G1.5 mm² 320 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593798 250 V/AC, 50 Hz, 16 A 3500 W (max.) 6 yes yes (bipolar) no 2.8 m H05VV-F 3G1.5 mm² 320 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593799 250 V/AC, 50 Hz, 16 A 3500 W (max.) 6 no no no 2.8 m H05VV-F 3G1.5 mm² 295 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593800 250 V/AC, 50 Hz, 16 A 3500 W (max.) 6 no no no 2.8 m H05VV-F 3G1.5 mm² 295 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593801 250 V/AC, 50 Hz, 16 A 3500 W (max.) 6 no yes (bipolar) no 1.4 m H05VV-F 3G1.5 mm² 320 x 50 x 40 mm -10 °C to +50 °C 10% to 90%
1593802 250 V/AC, 50 Hz, 16 A 3500 W (max.) 6 no yes (bipolar) no 1.4 m H05VV-F 3G1.5 mm² 320 x 50 x 40 mm -10 °C to +50 °C 10% to 90%