User manual
• Whenyoucarrythelaboratorypowersupplyfromacoldtoawarmroom,condensationmayform.Thisposes
theriskoffatalinjuryduetoelectricshock.Thus,alwaysallowthelaboratorypowersupplytoreachroom
temperaturebeforeconnectingittothepoweroutletandturningitonand/orusingit.
• Beforeandduringuse,makesurethatyourhands,shoes,clothing,theoorandthedeviceitselfaredry.
• Makesurethattheinsulationofthelaboratorypowersupply,ofthesafetyplugs,ofallconnectedcablesand
ofthemainscableisnotdamagedordestroyed.Avoidusingunprotectedwires.
• Themainsoutletmustbelocatedneartothedeviceandbeeasilyaccessible.
• Neverpullthemainsplugfromthesocketbypullingatthecable.Alwayspullitfromthemainssocketusing
theintendedgrips.
• Unplugthemainsplugfromthemainssocketifyoudonotusethedeviceforanextendedperiodoftime.
• Disconnectthemainsplugfromthemainssocketinthunderstormsforreasonsofsafety.
• Makesurethatthemainscableisnotsqueezed,bent,damagedbysharpedgesorputundermechanical
stress.Avoidexcessivethermalstressonthemainscablefromextremeheatorcold.Donotmodifythe
mainscable.Otherwisethemainscablemaybedamaged.Adamagedmainscablecancauseadeadly
electricshock.
• Donottouchthemainscableifitisdamaged.First,powerdowntherespectivemainssocket(e.g.viathe
respectivecircuitbreaker)andthencarefullypullthe mains plug from the mains socket. Never use the
productifthemainscableisdamaged.
• A damaged mains cable may only be replaced by the manufacturer,a workshop commissioned by the
manufacturerorasimilarlyqualiedperson,soastopreventanydanger.
• Neverpluginorunplugthemainsplugwhenyourhandsarewet.
• Neverpouranyliquidsoverelectricaldevicesorputobjectslledwithliquidrightnexttothedevice.Ifliquid
oranobjectenterstheinteriorofthedevicenevertheless,rstpowerdowntherespectivesocket(e.g.switch
offcircuitbreaker)andthenpullthemainsplugfromthemainssocket.Donotoperatetheproductanymore
afterwards,buttakeittoaspecialistworkshop.
• Whenusingthe device,donotcarryany conductivemetalobjectsor jewelrysuchaschains,bracelets,
rings,etc.
• Neverleavethelaboratorypowersupplyunattendedduringuse.
• Shieldallconnectedunitsfrommalfunctionandfromexcessvoltage.
• Connectingseveraldevicesininseriesmaycausedangerousvoltagewhichcanposeariskoffatalinjury.
Heedthelowvoltageguideline.
• Duringuse,thelaboratorypowersupplyproducesheat.Neverinsertanyobjectsintotheproduct’sairvents
anddonotobstructventilationinanyway.Thepowersupplyiscooledprimarilyviaconvection.Thus,never
coverthelaboratorypowersupply.
• Incasesafeoperation isnolongerguaranteed,ceaseuse of thedeviceimmediatelyandshieldit from
unintendeduse.Safeoperationisnolongerguaranteedwhen:
- thepowersupplyisvisiblydamaged,
- thepowersupplynolongerfunctions,
- thepowersupplywasstoredforanextendedperiodunderadverseconditionsor
- iftheproductwasdamagedduringtransport.
• Donotusethelaboratorypowersupplyasacharger.
• Thelaboratorypowersupplyisnotapprovedforuseonpersonsoranimals.
• Openinganycoversontheproduct or removing parts – unless this is possible byhand–mayexpose
voltage-carryingcomponents.Thisposestheriskoffatalinjuryduetoelectricshock!
• Disconnectthedevicefromthepoweroutletbeforeopeningit.
• Capacitorslocatedinthelaboratorypowersupplymaystillbechargedevenwhenthedeviceisunplugged.
• Onlyusefusesofthespeciedtypeandratedcurrent.Theuseofmendedfusesisnotpermittedasthis
posesarehazard!
• Forinstallationsinindustrialfacilities,followtheaccidentpreventionregulationsforelectricalsystemsand
equipmentofthegovernmentsafetyorganizationorthecorrespondingauthorityforyourcountry.
• Inschoolsandeducationalinstitutions,hobbyanddo-it-yourselfworkshops,theuseofthelaboratorypower
supplymustbesupervisedbytrainedstaff.
• Pleasehandletheproductcarefully.Jolts,impactsorafallevenfromalowheightcandamagetheproduct.
• Alsoobservethesafetyandoperatinginstructionsofanyotherdeviceswhichareconnectedtotheproduct.
• Consultanexpertwhenindoubtaboutoperation,safetyorconnectionofthedevice.
• Maintenance,modicationsandrepairsaretobeperformedexclusivelybyanexpertorataqualiedshop.
• If you have questions which remain unanswered by these operating instructions, contact our technical
supportserviceorothertechnicalpersonnel.
Operating elements
1 LEDdisplay“A”foroutputcurrent
2 LEDdisplay“V”foroutputvoltage
3 Controldial“COARSE”forroughvoltageadjustment
4 Controldial“FINE”forexactvoltageadjustment
5 Plussocketfordirectcurrentoutput
6 Socketforground(yellow-green)
7 Minussocketfordirectcurrentoutput
8 On/offswitch
9 Controldial“CURRENT”foroutputcurrentlimit
10 LEDdisplay“CV”foroutputvoltageregulation
11 LEDdisplay“CC”foroutputcurrentregulation
12 Airvents
13 Fuseholder
14 Mainssocket
Operating instructions
Version 04/16
BT-155 Laboratory power supply
Item no. 1389713
Intended use
Thislaboratorypowersupplyfunctionsasapotential-freesourceofpowerfortheoperationoflow-voltageunits.Ithasbeen
developedforuniversaluseintheresearch,development,manufacturing,serviceandtrainingelds.Theunitstobeoperated
areconnectedviathesocketsonthefrontofthedevice.Alloperatingcontrolsandindicatorshavebeenneatlyarrangedto
simplifyuse.Thecorrespondingpowerandvoltagevaluesareeasilyvisibleonthehigh-contrastLEDdisplay.Thecontroldial
onthefrontofthedeviceisusedtosetcurrentandvoltagesvalues.Thecurrentconsumptionofaconnectedunitmaynot
exceedthemaximumamperageaslistedundertechnicaldata.
Thelaboratorypowersupplyhasaprotectionagainstoverloadandvoltagereversal.ThedeviceconformswithprotectionclassI.
Ithasbeenapprovedforconnectiononlytoagroundedpoweroutletandalternatingvoltageof230V/AC,50Hz.
Operationunderadverseambientconditionsisnotpermitted.Adverseambientconditionsaredenedassuch:
• wetnessorhighhumidity
• dustandammablegases,vaporsorsolvents
• thunderstormsand/orsimilarconditions(avoidstrongelectrostaticeldsingeneral)
Forsafetyandapprovalpurposes(CE),youmustnotrebuildand/ormodifythisproduct.Ifyouusetheproductforpurposes
otherthanthosedescribedabove,theproductmaybedamaged.Inaddition,improperusecancausehazardssuchasshort
circuiting,re,electricshocketc.Readtheinstructionscarefullyandkeepthem.Makethisproductavailabletothirdparties
onlytogetherwithitsoperatinginstructions.
ThisproductcomplieswiththestatutorynationalandEuropeanrequirements.Allcompanynamesandproductnamesare
trademarksoftheirrespectiveowners.Allrightsreserved.
Delivery content
• Laboratorypowersupply
• Mainscable
• Operatinginstructions
Up-to-date Operating Instructions:
1. Openwww.conrad.com/downloadsinabrowserorscanthedisplayed
QRcode.
2. Select document type and language and enter the item number
into the search eld.After submitting the query you can download
displayedrecords.
Explanation of symbols
Thissymbolindicatesahealthhazard,e.g.electricshock.
Theexclamationmarkindicatesspecicrisksassociatedwithhandling,functionanduse.
The“arrow”symbolindicatesspecialtipsandoperatinginformation.
Theproductisintendedforuseonlyinindoordryspaces,itmaynotbecomemoistorwet.
ThisdeviceisCEcompliantandfulllsallapplicableEuropeanguidelines.
Groundpotential
Protectivegroundwireconnection;donotloosenthisscrew.
Safety instructions
Read the operating instructions carefully and especially observe the safety information. If you do not
follow the safety instructions and information on proper handling in this manual, we assume no liability
for any resulting personal injury or damage to property. Such cases will invalidate the warranty/guarantee.
• ThelaboratorypowersupplyconformswithprotectionclassIandissuitedforconnectiononlytoagrounded
poweroutlet(230V/AC,50Hz).Makesurethatthegroundconnectionisnotdefective/interruptedasthere
isariskoffatalinjuryincaseofmalfunction.
• Thisproductisnotatoy,keepitoutofthereachofchildren.
Childrencannotrecognizethedangersthatmayarisewhenhandlingelectricaldevices.Childrenmayalter
settingsorinsertobjectsintotheairventsonthelabpowersupply.Thisposesariskoffatalinjurydueto
electricshock!Alwaysusetheproductoutofthereachofchildren.
• Donotleavepackagingmateriallyingaroundcarelessly.Thesemaybecomedangerousplayingmaterial
forchildren.
• Thelaboratorypowersupplymaybesetupandusedonlyindry,closedindoorspaces.Itmaynotbecome
moistorwet.Thepowersupplymaynotbeexposedtoextremetemperatures,directsunlight,vibrationsor
mechanicalstress.
• Usethelaboratorypowersupplyonlyinmildclimates,neverinthetropics.Reviewthesectionon“Technical
data”toseethepermittedambientconditionsforoperation.
• Choosealocationforthelaboratorypowersupplythatisstable,even,cleanandsufcientinsize.
• Donothaveanyopenamesinthedirect vicinityofthelaboratorypower supplyanddonotplace any
containerswithliquidsonornearthedevice.