Manual

BatteryMINDer
©
Model 12248-A-ODY
Rev. D-050509 Page 25 P/N VDC12248-A-ODY-MNL
DETAILED SPECIFICATIONS -
VDC Model No. 12248-A-ODY (con’t.)
Absorption mode transitions to Float mode conditions:
Mode:
1) Charging Current demanded by battery is less than 100
mA after 1 hour
2) 20 Hours Time-out: after 20 Hours unit switches to Float
Charge Mode
Absorption mode Thermal Runaway Protection: Stops Charg-
ing when the second current sample is larger the first current
sample (Positive dI/dt)
Switch to Float mode in Bulk charge or Absorption mode
when Battery type Button is Pressed For 3
Seconds or longer.
Float Charge output Voltage control 13.4 ±0.25 Vdc
Float Charge current control (8A Rate) 4 Adc±0.25
Float charge transitions to PWM Float Charge Mode after 1
Hour
Float Pulse Charge voltage control Upper level 14.0V ±0.25
Vdc
Lower level 13.0V ±0.25 Vdc
Float Pulse Charge current control (8A Rate) 4 Adc ±0.25