User guide

11 TP10330
and OFF is in the down position. The connectors for the
PHOTO HEAD (scanner) and the BATCHER (Valve, Lift
Wheel etc) are locking connectors. They cannot be installed
incorrectly. The PHOTO HEAD input is a 4 pin white nylon or
5 pin round male connector and the BATCHER is a 4 pin
round black male connector.
The current rating of the BATCHER fuse may depend on the type
of device supplied. Replace only with the type supplied with the
DCU-600. The fuse on models with modular power connectors
is mounted internal. The fuse in these models should only be
replaced by qualified personal.
CAUTION: NEVER EXCEED THE FUSE
RATING AS THIS COULD CAUSE FIRE,
PERSONAL INJURY OR PERMANENT DAM-
AGE TO THE EQUIPMENT
Connect the DCU-600 ONLY to a 115 volt 15 amp
GROUNDED outlet for safety and correct operation.
BATTERY REPLACEMENT
Over a period of time and usage the batteries in all electronic
equipment should be replaced so the unit will continue to func-
tion properly. The DCU-600 uses the batteries to protect the
stored data when the power is off. We recommend replacing the
batteries every two (2) years. We suggest writing the date of
purchase in the manual and on the bottom of the case. As a re-
minder, record the battery replacement date (two years from
purchase) in both locations. You should up-date the replacement
date every two years, and have the batteries replaced by quali-
fied personnel.
Use ONLY DURACELL alkaline size AA battery.
-------------------------- CAUTION --------------------------
The unit MUST BE unplugged from the 115 volt outlet before
attempting to replace the batteries or any procedure which
requires the removal of the cover on the unit. The unit should not
be plugged back into a power outlet until the cover has been
secured back on the unit; OTHERWISE, YOU MAY EXPERI-
ENCE AN ELECTRICAL SHOCK or damage the unit.
SCANNER (optical sensor) The reflective modulated scanner
senses material by reflection of light (from the scanner) off of the
material being counted. This is usually mounted on a fold plate of
the folder, scanning between the frame. A magnet holds the
scanner in place. Two type of scanners are available, modulated
and non-modulated
CAUTION: The DCU series of counters and batch
counters will not work with the old style U shaped incan-
descent break beam photo arm.