Specifications

HBZTX6-IN-4 Page 14
6.6 Connecting the Network Keyboard
These are described in the keyboard instructions as are the BAX-RKIT for expanding the
network.
Connect the keyboard using the RJ45 connector.
CAUTION: Each of the modules on your BaxNet network have an address. If two units share
the same address then the network will not work. The ZTX6 address is set in the on-screen
menus.
The keyboard has built in network termination and/or biasing. For most small to medium
sized installations, it should not be necessary to change the switches from their default
settings. Only for large installations should your network require biasing and/or terminating.
Contact Baxall Security Limited for advice. The switches are located on the front of your
ZTX6. The default setting for switches 1, 2 and 3 is OFF. Switch 4 is not used.
Network setting Switch 1 Switch 2 Network setting Switch 3
Biased ON ON Terminated ON
Not Biased* OFF* OFF* Not Terminated* OFF*
6.7 Connecting the Power
Your ZTX6 is supplied with a 230V ±10%, 47 - 63Hz AC to 12V DC PSU. It is fitted with a
non-removable power cord which must be terminated with a suitable three pin mains plug.
REFER TO WIRING INSTRUCTION LABEL ATTACHED TO MAINS LEAD. Provision for
secure isolation from the mains in accordance with your national wiring regulations must also
be provided.
Connect your ZTX6 and keyboard
Switch on the power
For the first 5 seconds after the power is initially connected the keyboard LCD should display
something like:
Baxall Security
ZKX3/K Vx.x 9600
(The number x.x indicates the software version)
And the monitors should display:
ZTX6 MKII VERSION : 1.xx
BY
BAXALL SECURITY LTD
UNIT ID 9
FIRMWARE VER : wwxxyyzz