Specifications

HBZTX6-IN-4 Page 26
The factory default setting is with sequences 1 and 2 defined already as, respectively,
cameras 1 – 16 and cameras 17 – 32, all with a dwell time of 5 seconds. The other
sequences are undefined.
9.3 The Camera/Rx menu
Where Rx = receiver.
Use
and up-arrow or Joystick (together) or and down-arrow or Joystick (together) to
step through the camera inputs.
The line below the word Title can be edited using the text editor - see Section 8.7, Entering
And Changing Text.
Input present YES/NO
Select NO to prevent camera selection and stop the channel from being displayed.
Rx attached NONE/AC/DC
This option switches the telemetry on and off for that input, and specifies the type of
receiver (AC/DC) if one is present. If it is selected as AC/DC, telemetry is transmitted
when a telemetry key is pressed. The default setting for the Rx attached parameter is
AC for each input. That is, telemetry is switched on and the receiver type is AC. To
obtain the optimum performance from the system, particularly for the operation of
Global commands, each input should be correctly set to AC, DC or NONE.
Telemetry Mode STANDARD/ALTERNATE
See the trouble shooting section for an explanation. Standard suits most installations.
Preset Mode STANDARD/ENHANCED
The recommended mode is ENHANCED setting of presets. This mode is both faster and
more convenient. Its use is described in section 9.11.
Note: If you have a receiver manufactured before March 1996 then you must use
STANDARD mode. This is described in Appendix A.
3 Camera/Rx menu
Camera number : 19
Title:
Camera 19
Input present : YES
Rx attached : AC
Telemetry mode : STANDARD
Preset mode : ENHANCED
Return to main menu