Specifications

HBZTX6-IN-4 Page 29
STACK = As each response arrives it is shown on the next available alarm-monitor
(according to the alarm monitor list, section 9.10). Once all the alarm-monitors are full the
next response is placed in a queue. When an response is cleared it is replaced by the next
response in the queue.
SWITCH = The first response is shown on all
the alarm monitors. Once it is cleared the next
response is displayed on all alarm monitors.
ROTATE = This is the same as SWITCH however subsequent responses are cycled in a
sequence which uses the ‘Transp. alarm timeout’ as its dwell-time. Rotate does not work in
TRANSP. or TIMEOUT response modes and must be used in the ACK response mode.
Note: in rotate mode the alarm outputs are disabled.
End action
This can be set as RETURN or NONE. RETURN will return the monitors to their pre-alarm
states when the alarms are cleared. NONE will leave the monitors in their alarm states.
9.6 Alarm Monitors Menu
Use this menu to select which monitors the responses are displayed on. The options are
DISPLAY/NO DISPLAY per monitor.
In LAST, SWITCH and ROTATE display modes, the current response is displayed on all the
monitors selected here. In STACK display mode, the first response is displayed on the
lowest numbered monitor selected here, the second on the second lowest etc. As the
responses are cleared the next response (next response which had no monitor to display on)
drops onto the monitor which contained the response just cleared.
4.5 Alarm monitors menu
Monitor number 1: DISPLAY
2: NO DISPLAY
3: NO DISPLAY
4: NO DISPLAY
5: NO DISPLAY
6: NO DISPLAY
7: NO DISPLAY
8: NO DISPLAY
Return to alarm main menu