Specifications

HBZTX6-IN-4 Page 32
9.10 Response Setup
Responses are triggered by alarms or network events (see section 9.9). They display a title;
switch a camera to the alarm monitor; move it to a preset position; generate a network
event; activate the alarm-output relays; and generate an audible warning at the keyboards.
To step through the 32 responses:
Use and the up-arrow key or Joystick; or and the down-arrow key or
Joystick.
or,
type the number in the first field.
To change the settings:
Use the left-arrow/right-arrow key or Joystick to select the field you want to
change.
Change the title using the text editing described in section 8.7
Select the camera, the preset and any network events (1-255) in the next 3 fields.
Zero represents no action. See section 9.11 for setting presets.
Select the alarm-output relays in the ‘Activate relays’ field (‘1 ONLY’, ‘2 ONLY’, ‘1
AND 2’ and ‘NONE’).
Select the urgency of the keyboard beep in ‘Generate sound’ options are ‘NONE’,
‘SHORT’, ‘MEDIUM’ and ‘LONG’. The beep sounds on all keyboards.
To respond to events from other ZTX6s or ZMXs on the network see the Event responses
menu in section 9.9.
4.2 Response setup
Response number :01
Title:
Alarm 1
Switch to camera :01
Camera preset :00
Generate event :255
Activate relays :1 ONLY
Generate sound :SHORT
Return to alarm main menu