Technical data

Servicing
120-393 632.4 04.08 Fh
PARAMOUNT two 30 - 115 kW 65
Dismantling of the gas burner (PARAMOUNT two 80 D)
Disconnect the connecting lines to the fan.
Disconnect ionisation line.
Disconnect ignition cable.
Disconnect fastening screws of the bracket on the housing lid.
Disconnect the screw connections of the gas connection pipe at
the mixing chamber and the gas valve.
Remove the gas connection pipe and the gas injector.
Disconnect the gas connection pipe at the gas valve and remove
gas valve.
Undo the 5 fastening screws at the mixing chamber/heat ex-
changer.
Remove bracket.
Disconnect flue silencer from the bracket.
Pull out the burner together with mixing chamber, fan and ea-
haust gas muffler to the front (see figure 19)siehe Abb. 21
Clean burner pipe with soft brush.
Use new seals when installing.
Fig. 21: Dismantle of the gas burner (PARAMOUNT two 80 D)
Pull out burner with mixing cham-
ber and flue silencer.
Remove bracket.
Disconnect gas con-
nection pipe.
Remove gas injector.
Remove gas con-
nection pipe.
Remove gas valve.
Disconnect flue silencer from bracket (under
the housing lid).