Operating instructions

5.0 Clearances
8
5.1 Clearances around the Boiler
1. The minimum clear spaces needed around the boiler
measured from the casing are as follows:
Top - 200mm
Bottom - 200mm
Both sides - 5mm
Front - 500mm (For Servicing)
- 5mm (In Operation)
2.
These areas must not be obstructed in any way.
Blocking the clearance spaces may result in the boiler
overheating and damage may occur.
3. The gas burning compartment of your boiler is
completely sealed from the room in which it is fitted.
Products from the combustion of gas are vented to the
outside through the flue terminal which must be kept free
from obstruction as this would interfere with the correct
operation of the boiler.
4.
Where the appliance is installed in a cupboard or
compartment no air vents are required.
The label affixed
to the front of the boiler must not be removed. The
information will be required by service engineers in the
future. The compartment should be large enough to house
the boiler and ancillary equipment only.
5.
IT SHOULD NOT BE USED AS A STORAGE
CUPBOARD.
200mm
850mm
490mm
200mm
5mm Min
5mm Min
5mm
500mm
For Servicing
Purposes
Fig. 5
Fig. 6
In Operation
(1 in 20)
320mm
Never Hang Any Items Over The Appliance