Quick Start Manual

8.0 Installation
26
© Baxi Heating UK Limited 2005
8.6 Fitting the Flue (Cont)
8. Ensure the inner flue support bracket is positioned in
the flue (Fig. 24).
9. Engage the flue into the flue elbow using soap
solution to ease the engagement ensuring the flue is
assembled as shown (Fig. 25).
10. Place the gasket over the flue exit on the boiler
(Fig. 25).
11. Slide the flue assembly through the hole in the wall.
Ensure angled inner end slopes downwards (Fig. 26).
12. Engage the elbow on to the flue connection on top
of the boiler. Secure with the four screws supplied in
the kit.
13. Make good between the wall and air duct outside
the building ensuring the 3° drop between the terminal
and elbow.
14. The flue trim should be fitted once the installation
is complete and the flue secure
(Fig. 26). Apply a suitable mastic to the inside of the
trim and press against the wall finish, making sure the
brickwork is dust free and dry.
15. If necessary fit a terminal guard (see Section 7.9).
VERTICAL FLUEING
1. Only a flue approved with the Baxi Combi HE Plus
Boiler Range can be used.
2. For information on vertical flues consult the Baxi
Flue Guide Brochure or Notes for Guidance supplied
with the vertical flue pack.
Gasket
Flue Trim
Inner Flue Support Bracket
Flue
Flue Elbow
Fig. 24
Fig. 26
Fig. 25