Quick Start Manual

11.0 Fitting the Outer Case
35
© Baxi Heating UK Limited 2005
11.1 Fitting The Outer Case
1. Fit the outercase to the appliance ensuring that the
four slots in the side flanges align with the hooks on
the chassis (Fig. 38).
2. Insert the two fixing screws into the sides of the
chassis (Fig. 39).
3. Close the lower door panel against the retaining
magnets (Fig. 39).
4. Instruct the user in the operation of the boiler
controls. Hand over both the Users Operating and
Installation and Servicing Instructions, giving advice on
the necessity of regular servicing.
5. Advise the user that a plume of vapour from the
flue terminal is normal, and that there is no need for
concern.
6. Advise the user that if intelligent pre-heat is on, pre-
heating will not occur for the first week of operation.
7. Set the User preferences. See User Label on lower
door panel (Fig. 38) or user’s operating instructions
(set CH/DHW temperatures).
8. Carefully read and complete all sections of the
Benchmark Commissioning Checklist at the rear of this
publication that are relevant to the appliance and
installation. These details will be required in the event
of any warranty work. The publication must be handed
to the User for safe keeping and each subsequent
regular service visit recorded.
9. For IE, it is necessary to complete a “Declaration of
Conformity” to indicate compliance to I.S. 813. An
example of this is given in I.S. 813 “Domestic Gas
Installations”. This is in addition to the Benchmark
Commissioning Checklist.
Fig. 38
Fig. 39
Lower Door Panel
Outercase Fixing Screws
Lower Door Panel
Retaining Magnet
User
Label