Quick Start Manual

13.0 Changing Components
41
© Baxi Heating UK Limited 2005
13.10 Three-Way Diverter Valve (Head Only)
(Fig. 55)
If only the head needs replacing:
1. Unplug the wiring harness from the 3-way diverter
valve.
2.Depress the clip and revolve the head through 30°
and remove.
3. Fit replacement head and reassemble in reverse
order.
13.11 Three-Way Diverter Valve (Complete)
(Fig. 56)
1. Drain the boiler (see Section 13.1 paragraph 2 & 3).
2. Unplug the wiring harness from the 3-way diverter
valve.
3. Remove the four socket screws retaining the 3-way
valve.
4. Remove the 3-way valve.
5. Fit the new 3-way valve ensuring the gasket is in
place and that the spigots are at the top to fit into the
recesses on the manifold and reassemble in reverse
order.
Fig. 55
Wiring Harness
Fits Here
Fig. 56
Clip
Three-Way
Diverter Valve
Head
Wiring Harness
Fits Here
Three-Way
Diverter Valve
Spigot
Gasket